![GAI-Tronics 13382 Installation And Operation Manual Download Page 16](http://html1.mh-extra.com/html/gai-tronics/13382/13382_installation-and-operation-manual_3192177016.webp)
Pub. 42004-462A
Model 13382 WiFi and 13383 VoIP Addressable Amplified Speakers
Page 14 of 24
f:\standard ioms - current release\42004 instr. manuals\42004-462a.doc
12/13
VoIP PCBA Configuration
For the first time configuration of the VoIP PCBA, power the unit by connecting dc power to TB101 and
connect Ethernet port of the VoIP PCBA to a 10/100 Base-T Ethernet network. Refer to Figure 7.
The easiest way to get started is to make a network connection to the unit and log on via a web browser.
The unit is initially set with a static IP address:
IP address
192.168.1.2
A user name and password will be requested. The initial factory settings are:
User Name
user
Password
password
Changing the user name and password is recommended. This security measure helps to prevent
unauthorized changes to the VoIP PCBA Interface’s configuration.
N
OTE
:
The audio output level is set by configuring the Hands-free Output on the Audio Settings
webpage during the configuration of the speaker.
VoIP PCBA Initial Network Configuration
Each VoIP PCBA must be set up for the network prior to installation. Assign a local ID, domain, proxy,
and registrar.
Assign a host name
The host name provides identification of the different VoIP PCBAs on the
network.
Test
Verify that calls can be made successfully.
Maintain
Monitor alarms. Set up auto-updates.
Refer to Pub. 42004-482 for detailed programming instructions of this VoIP device.
Closing the Addressable Amplified Speaker
Assemble the speaker sections and tighten the front panel screws to 16 to 20 in-lbs. of torque.