Installation as a Wall Receptacle
1. Arrange the cable so that the DB25 male connector is located at the amplifier enclosure and the
cable’s DB25 female connector is located at the wall receptacle. Remove the thumb screws from the
female DB25 connector. See Figure 1.
2. Route the 25-foot cable/plug assembly inside the wall from the amplifier location to the desired wall
receptacle location, and mount it by using a single gang wall plate mounting bracket (such as L-Com
WPMB1). Make the connection in accordance with the appropriate electrical code.
3. Install the DB25 female connector on the supplied wall plate, using the included two 4-40 jack
screws to attach the connector to the wall plate.
Figure 1. Installation as a Wall Receptacle
4. Install the wall plate using the two mounting screws provided.
5. After all connections have been made, plug the DB25 male connector into the receptacle at the
amplifier enclosure.
6. Plug the subset plug into the DB25 wall receptacle. Be sure that the connector housing seats fully
into place, and use the DB25 connector thumb screws to secure the connector.