Voice Annunciation PCBA Field
Installation Kit
M
ODEL
12562-109
Confidentiality Notice
This manual is provided solely as an operation, installation, and maintenance guide and contains sensitive
business and technical information that is confidential and proprietary to GAI-Tronics. GAI-Tronics
retains all intellectual property and other rights in or to the information contained herein, and such
information may only be used in connection with the operation of your GAI-Tronics product or system.
This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any third party.
General Information
The Model 12562-109 Voice Annunciation (VA) PCBA Field Installation Kit consists of a printed circuit
board assembly (PCBA), two lithium AA batteries, and three standoffs for mounting the VA PCBA to
the Main PCBA. The kit is designed to be used only in the following GAI-Tronics RED ALERT
®
Series
Emergency Telephones:
393-00x
393AL-00x
394AL-00x
396-00x
397-00x
397-00xCB
397-00xRT
397-00xTP
398-00x
398-00xCB
398-00xRT
398-00xTP
Electrostatic Discharge (ESD) Protection
Your telephone may have an earth ground terminal provision. If so, ensure that it is connected to ground
in accordance with all local safety regulations and the National Electrical Code (NEC). Grounding has to
be ensured for safe and stable communications. Do not use long and coiled ground wires. Trim ground
wires to the required length. Use a star configuration whenever possible.
Installation
Removing the Front Cover
Use the Model 233-001 Security Screwdriver (Torx T-25 security tip) to remove the four (or six,
depending on the telephone model) front cover security screws, and remove the front cover after
disconnecting the telephone line.