background image

Pub. 42004-401D 

GAI-TRONICS 3030 KUTZTOWN RD.  READING, PA  19605 USA

 

610-777-1374  

  800-492-1212  

  Fax:  610-796-5954 

V

ISIT WWW

.

GAI

-

TRONICS

.

COM FOR PRODUCT LITERATURE AND MANUALS

 

G A I - T R O N I C S ®  

A   H U B B E L L   C O M P A N Y  

Model 10961-101 

AMI Centra-Page Interface 

Confidentiality Notice 

This manual is provided solely as an operational, installation, and maintenance guide and contains 
sensitive business and technical information that is confidential and proprietary to GAI-Tronics.  GAI-
Tronics retains all intellectual property and other rights in or to the information contained herein, and 
such information may only be used in connection with the operation of your GAI-Tronics product or 
system.  This manual may not be disclosed in any form, in whole or in part, directly or indirectly, to any 
third party. 

General Information 

GAI-Tronics’ Centra-Page systems provide dependable paging and party line communications for rugged 
and hazardous industrial facilities.  Centra-Page systems feature centrally located electronics that provide 
environmental protection and unitized amplification for easy maintenance. 

Standard Centra-Page cabinets can support up to 30 handset stations, and in most cases, up to 60 paging 
speakers.  Alarms and telephone interfacing can be added to Centra-Page systems with the addition of a 
Model 10959-208 Audio Messenger Interface (AMI) and a Model 10961-101 AMI Centra-Page Interface. 

The Model 10961-101 AMI Centra-Page Interface, in combination with the AMI, can replace the Model 
H97019 Programmable Tone/Speech Generator and the Model 10448-202 Telephone Interface for 
Centra-Page systems or the Model GTB93017 Programmable Telephone Interface in CP/P II systems. 

The Model 10961-101 AMI Centra-Page Interface is designed to provide five alarm inputs to activate the 
Model 10959-208 AMI’s tone/speech generator when both are mounted in a Model 10468-002 Centra-
Page Central Cabinet and are properly configured. 

The AMI Centra-Page Interface can provide Centra-Page systems access to the public telephone network.  
The telephone line coupler is designed for loop start operation with bridged ringing.  This coupler is 
registered by the FCC number ADGOT01B46055.  The Ringer Equivalence Number (REN) is 0.1A, with 
an RJ11C connection. 

Summary of Contents for 10961-101

Page 1: ...t provide environmental protection and unitized amplification for easy maintenance Standard Centra Page cabinets can support up to 30 handset stations and in most cases up to 60 paging speakers Alarms and telephone interfacing can be added to Centra Page systems with the addition of a Model 10959 208 Audio Messenger Interface AMI and a Model 10961 101 AMI Centra Page Interface The Model 10961 101 ...

Page 2: ...tains a priority alarm test panel and a telephone interface panel The 69542 001 PCBA and 69407 002 I O Controller PCBA are mounted on the rear along with a power terminal block The AMI Centra Page Interface outline is shown in Figure 1 IN USE SUBSET TELEPHONE ACCESS NIGHT DAY DISCONNECT TELEPHONE INTERFACE PRIORITY ALARM TEST CLEAR 5 4 3 2 1 Figure 1 Model 10961 101 AMI Centra Page Interface ...

Page 3: ...eplacing existing equipment remove the tone generator telephone interface and the associated wiring prior to installing the Model 10961 101 Interface The Model 10961 101 AMI Centra Page Interface and the Model 10959 208 AMI should be installed in the Centra Page central cabinet at the same time Allow 6U of open space immediately below the Model 10461 002 Card Rack in the lowest position in the cab...

Page 4: ...andard ioms current release 42004 instr manuals 42004 401d doc 02 16 IN USE ACCESS DISCONNECT TELEPHONE INTERFACE PRIORITY ALARM TEST TELEPHONE SUBSET NIGHT DAY CLEAR 1 2 3 4 5 Figure 2 Centra Page Central Cabinet with AMI and AMI Centra Page Interface front of center section ...

Page 5: ... p standard ioms current release 42004 instr manuals 42004 401d doc 02 16 AUDIO DIGITAL INPUTS DIGITAL OUTPUTS ETHERNET SYSTEM CLASS 2 CLASSE 2 12 24 VDC PBX PAGE PARTY Figure 3 Centra Page Central Cabinet Showing front of rear section and the rear of the center section ...

Page 6: ...Pub 42004 401D Model 10961 101 AMI Centra Page Interface Page 6 of 22 p standard ioms current release 42004 instr manuals 42004 401d doc 02 16 Figure 4 Wiring of Central Cabinet s wall mounted section ...

Page 7: ...42004 401D Model 10961 101 AMI Centra Page Interface Page 7 of 22 p standard ioms current release 42004 instr manuals 42004 401d doc 02 16 Figure 5 Wiring of the rear of the Central Cabinet s center section ...

Page 8: ...ctor to the 61531 034 cable assembly See Figure 6 Using this 10 position removable terminal block connect the six wires from positions 1 through 6 of the 61531 034 cable assembly The brown and black wires from positions 9 and 10 are not connected to this terminal block Refer to Figure 5 Figure 6 61531 034 Cable Assembly Connector from AMI TB3 Audio Terminal Wire Color Function TB3 1 Purple Page or...

Page 9: ...the outside of TB1 mounted on the AMI Centra Page Interface plate and the 61531 040 cable assembly to the inside of TB1 TB1 on AMI Centra Page Interface Panel Terminal Wire Color Function TB1 1 Red 24 V dc TB1 2 Black of 24 V dc TB1 3 Green Ground 7 Connect the 61531 033 cable connector to TB1 on the 69542 001 PCBA 8 Connect the 61531 034 cable connector the end without the brown and black wires t...

Page 10: ... Centra Page Cabinet Back Panel Power TB11 Terminal Wire Color Function TB11 1 Red 24 V dc TB11 2 Black of 24 V dc TB11 3 Green Ground 11 Connect the red and black wires of cable assembly 61531 039 to the TBX05 terminal block on the card rack located in the lowest mounting position Connect the green wire from the 61531 039 cable assembly and one end of the 61531 041 grounding wire to the grounding...

Page 11: ...o the central cabinet s back panel TB12 ALARM and TB13 INTERFACE Refer to Figure 4 Centra Page Cabinet Back Panel Alarm TB12 Terminal Wire Color Function TB12 4 Tan black Priority 1 TB12 5 White green Priority 2 TB12 6 Green white Priority 3 TB12 7 Black yellow Priority 4 TB12 8 Red Priority 5 TB12 9 Blue Reset TB12 10 Black Switch common TB12 11 NC Ground Centra Page Cabinet Back Panel Interface ...

Page 12: ...1 TBX04 11 Blue red Page common 15 Install the modular RJ11 splitter into the RJ11 jack on the rear on the AMI Connect the phone cable from the AMI Centra Page Interface into one of the splitter RJ11 jacks Connect the telephone line into the other splitter RJ11 jack 16 Remove the Flash Memory card from the AMI and replace it with the Flash Memory card that came with the AMI Centra Page Interface K...

Page 13: ...ation for the AMI Quick Test 1 Press the PRIORITY 1 button on the front of the Interface panel to play the Alarm 1 tone over the Centra Page station and the crew s quarters speakers 2 Press the CLEAR button on the front panel of the AMI Centra Page Interface to stop the alarm tone 3 Set the DAY NIGHT switch on the front of the AMI Centra Page Interface panel to Night Mode Call the AMI from an exte...

Page 14: ...MI Centra Page Interface communicating their state to the AMI Alarms and Paging Five alarms can be activated from the push buttons on the front panel of the AMI Centra Page Interface or from remote switches momentary N O The alarms can be cleared or reset using the push button on the front panel For convenience a remote switch can be connected to control each alarm Use terminal block TB11 on the C...

Page 15: ... up so that it is active when one or all of the first three alarms are played Jumpers P1 to P3 are used to select alarms 1 to 3 Putting the jumper across positions 1 and 2 makes the output inactive for that alarm and putting the jumper in positions 2 and 3 activates the output for that alarm The output is on TBX04 on the AMI Centra Page Interface s 69542 001 PCBA It is position 9 of TBX04 and will...

Page 16: ...al Cabinet can be used DayMode An attendant with access to a phone on the same line as the AMI and a Centra Page station answers the incoming call and pages the person being called When that person answers on party line 1 of the Centra Page system the attendant presses the ACCESS button to connect the phone line to the party line Upon completion of the call the attendant presses the DISCONNECT but...

Page 17: ... on the AMI and I O controller PCBA the AMI configuration must be changed Refer to the Model 10959 208 AMI manual GAI Tronics Pub 42004 345 and online help to set them up The charts below show the layouts for the inputs and outputs Input Layout for Default AMI Centra Page Configuration Inputs in ACT Configuration Where Input Terminal is Located Description 1 Input 1 on AMI TB2 Audio 2 1 Not used 2...

Page 18: ... controller TB7 1 2 Not used 26 Input 18 on I O controller TB7 3 4 Not used 27 Input 19 on I O controller TB7 5 6 Not used 28 Input 20 on I O controller TB7 7 8 Not used 29 Input 21 on I O controller TB7 9 10 Not used 30 Input 22 on I O controller TB7 11 12 Not used 31 Input 23 on I O controller TB7 13 14 Not used 32 Input 24 on I O controller TB7 15 16 Not used 33 Input 25 on I O controller TB8 1...

Page 19: ...n I O controller TB10 4 Not used 13 Output 5 on I O controller TB10 5 Not used 14 Output 6 on I O controller TB10 6 Not used 15 Output 7 on I O controller TB10 7 Not used 16 Output 8 on I O controller TB10 8 Not used 17 Output 9 on I O controller TB10 9 Not used 18 Output 10 on I O controller TB10 10 Not used 19 Output 11 on I O controller TB10 11 Not used 20 Output 12 on I O controller TB10 12 No...

Page 20: ...troller TB9 9 Not used 34 Output 26 on I O controller TB9 10 Not used 35 Output 27 on I O controller TB9 11 Not used 36 Output 28 on I O controller TB9 12 Not used 37 Output 29 on I O controller TB9 13 Not used 38 Output 30 on I O controller TB9 14 Not used 39 Output 31 on I O controller TB9 15 Not used 40 Output 32 on I O controller TB9 16 Not used NOTE The ground connections for the outputs on t...

Page 21: ...repairs will be made without charge Please include a written explanation of all defects to assist our technicians in their troubleshooting efforts Call 800 492 1212 inside the USA or 610 777 1374 outside the USA for help identifying the Regional Service Center closest to you Troubleshooting Problem Solution No activity Check the power on the AMI Centra Page Interface The interface does not answer ...

Page 22: ...Mechanical Enclosure Steel black fine textured paint finish Mounting Rack mount 5U in standard 19 inch Dimensions 8 72 H 19 00 W 1 82 D inches 221 5 482 6 46 2 mm Weight 5 lbs 2 27 kg Environmental Temperature range 32 F to 122 F 0 C to 50 C Contact Requirements Alarm and telephone inputs Priority 1 5 clear reset access and disconnect Dry contact momentary N O SPST 5 mA minimum Mode input day nigh...

Page 23: ... of the Contractor s personnel from the work site Re performance of services shall be Buyer s sole and exclusive remedy and in no event shall GAI Tronics warranty obligations with respect to services exceed 100 of the total cost of the services provided hereunder Warranty Periods Every claim by Buyer alleging a defect in the goods and or services provided hereunder shall be deemed waived unless su...