8.4 Switching on intensive mode

If particularly strong odours or vapours develop, you
can use intensive mode.

Push in the control knob and turn it clockwise to  ​⁠.

a

After approx. 6 minutes, the appliance automatically
switches to fan setting  ​⁠.

8.5 Switching off intensive mode

Turn the control knob anti-clockwise to  ​⁠.

8.6 Switching on interval ventilation

With interval ventilation, the ventilation switches on at
fan setting  ​⁠ for approx. 6 minutes every hour.

Push in the control knob and turn it clockwise to  ​⁠.

a

The illuminated ring on the control knob will be lit
orange while the ventilation system is switched on.

8.7 Switching off interval ventilation

Turn the control knob anti-clockwise to  ​⁠.

8.8 Using Home Connect to set the
appliance

You can set the appliance via the Home Connect app
and via a hob using the Home Connect app.

1.

Set up the Home Connect app. 
→ 

"Home Connect ", Page 8

2.

Establish the connection to the hob. 
→ 

"Connecting the downdraft ventilation to the hob",

Page 14

3.

Push in the control knob and turn it anti-clockwise to

​⁠.

8.9 Fan run-on

During the fan run-on, the appliance continues running
at a lower fan setting for a short time after switch-off
and then switches off automatically. The appliance
switches off the ventilation system after 20 minutes in
air recirculation mode and after 6 minutes in air extrac-
tion mode. The fan run-on reduces condensation in the
appliance.
While the ventilation system is switched on, the illumin-
ated ring on the control knob slowly flashes orange.
The fan run-on only starts in air recirculation mode and
if the appliance has been switched on for at least 2
minutes.
In automatic mode, the fan run-on starts in air recircula-
tion mode and in air extraction mode.
You can change the settings for the fan run-on in the
Home Connect app.

Switching off the fan run-on early

1.

Turn the control knob to  ​⁠.

2.

Turn the control knob to  ​⁠.

a

The appliance switches off the fan run-on early.

8.10 Resetting the saturation indicator

After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.

Note: 

When using a regenerative odour filter, set the fil-

ter type in the Home Connect app.

Requirement:

 After the appliance has been switched

off, the illuminated ring on the control knob flashes
white slowly three times for the grease filter saturation
indicator or flashes white rapidly six times for the odour
filter saturation indicator.

1.

Push in the control knob and turn it clockwise to  ​⁠.

a

The illuminated ring on the control knob flashes
white three times. The saturation indicator is reset.

2.

Turn the control knob to  ​⁠ again.

9  Home Connect

This appliance can be networked. You can send set-
tings to the appliance via a mobile device.
The Home Connect services are not available in every
country. The availability of the Home Connect function
depends on the availability of Home Connect services
in your country. You can find information about this at:
www.home-connect.com.
The Home Connect app guides you through the entire
login process. Follow the instructions in the Home Con-
nect app to configure the settings.

Tips

¡

Please consult the documents supplied by
Home Connect.

¡

Please also follow the instructions in the Home Con-
nect app.

Notes

¡

Please note the safety precautions in this instruction
manual and make sure that they are also observed
when operating the appliance via the Home Con-
nect app. 
→ 

"Safety", Page 2

¡

Operating the appliance on the appliance itself al-
ways takes priority. During this time it is not possible
to operate the appliance using the Home Connect
app.

¡

In networked standby mode, the appliance requires
a maximum of 2 W.

¡

If you need your device's MAC address to connect
to your home network, you can find this next to the
rating plate. → 

Page 20

9.1 Setting up Home Connect

Requirements

¡

The appliance is connected to the power supply and
is switched on.

¡

You have a mobile device with a current version of
the iOS or Android operating system, e.g. a smart-
phone.

¡

The mobile device and the appliance are within
range of your home network's Wi-Fi signal.

Summary of Contents for VL414115

Page 1: ...en User manual and installation instructions VL414115 Extractor hood Gaggenau ...

Page 2: ...orks perfectly at its installation location Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up to an altitude of max 4000 m above sea level Do not use the appliance With an external timer To extract hazardous or explosive sub stances and vapours To extract small parts and liquids 1 3 Restriction on user group This applian...

Page 3: ...from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is only possible to safely operate the ap pliance if the pressure in the room in which the heating appliance is installed does not drop ...

Page 4: ...rd or switch off the fuse in the fuse box Call customer services Page 20 Incorrect repairs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when repair ing the appliance If the power cord of this appliance is dam aged it must be replaced with a special connection cable which is available from the manufacturer or his Customer...

Page 5: ...4 Operating modes You can use your appliance in air extraction mode or circulating air mode 4 1 Air extraction mode The air which is drawn in is cleaned by the grease fil ters and conveyed to the exterior by a pipe system The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels not applicable to appliances that only discharge the air b...

Page 6: ...owly flashes White three times Grease filter saturation in dicator Switch off appliance quickly flashes White six times Odour filter saturation in dicator in air recirculation mode only Switch off appliance slowly flashes Orange Fan run on Light up Blue Home Connect Flash Blue Home Connect appliance is connected to the home network Flashing alternately Or ange and white Safety switch off function ...

Page 7: ...n the control knob lights up or ange 8 2 Switching off the appliance Turn the control knob anti clockwise to If the fan run on is activated the appliance contin ues to run for a short time after it is switched off Fan run on Page 8 8 3 Sensor control In automatic mode a sensor in the appliance detects the intensity of the cooking and roasting fumes De pending on the setting of the sensor sensitivi...

Page 8: ...n on early 8 10 Resetting the saturation indicator After cleaning the grease filter or after changing the odour filter the saturation indicator can be reset Note When using a regenerative odour filter set the fil ter type in the Home Connect app Requirement After the appliance has been switched off the illuminated ring on the control knob flashes white slowly three times for the grease filter satu...

Page 9: ...ted ring on the control knob lights up blue 2 In order to implement a setting turn the control knob to the required position Overview of the Home Connect settings Page 10 3 To save the setting exit the Home Connect settings menu in the same way Turn one notch anti clockwise to Turn the control knob two notches clockwise to Turn the control knob one notch anti clockwise to Displays on the illuminat...

Page 10: ...e Connect settings Page 10 3 To save the setting exit the Home Connect settings menu in the same way Turn one notch anti clockwise to Turn the control knob two notches clockwise to Turn the control knob one notch anti clockwise to 9 4 Overview of the Home Connect settings In the Home Connect settings you can adjust settings and network settings for Home Connect Knob position Setting Use Manual log...

Page 11: ...To save the connection exit the Home Connect set tings menu Opening or closing the Home Connect settings menu Page 9 7 After successfully connecting push in the control knob and turn it anti clockwise to Otherwise you will not be able to operate the appli ance via the Home Connect app Connection to the router unsuccessful 1 If a connection could not be established check the router and turn the con...

Page 12: ...knob flashes blue and white 2 Launch the Home Connect app on your mobile device and follow the instructions for automatic net work login Connecting more mobile devices to the same Home Connect account In the Home Connect app you can connect more mobile devices to your appliance if required Connecting more mobile devices to another Home Connect account Requirement A mobile device is connected to th...

Page 13: ...nect connection You can reset the connections you have saved on your home network and on the hob at any time 1 Open the Home Connect settings menu Opening or closing the Home Connect settings menu Page 9 a The illuminated ring on the control knob lights up blue 2 Turn the control knob clockwise to a After approx 30 seconds the illuminated ring on the control knob lights up green a The Home Connect...

Page 14: ...raft ventilation is at position You have the following options for connecting the appliances together Connecting appliances via the home network Connecting via the home network Page 14 Connecting appliances directly Connecting directly Page 14 10 1 Connecting via the home network If the appliances are connected to each other via your home network both the hood controls on the hob and the Home Conn...

Page 15: ...y a The appliance attempts to establish a connection again Connecting another hob to the downdraft ventilation In order to connect another hob to the downdraft ventil ation run through the direct connection again with the second hob 1 Switch off the Wi Fi on the first hob To do so follow the instructions in the hob s user manual 2 Start the connection for the second hob then start the connection f...

Page 16: ... selected Fan setting during inter val ventilation Selected Not selected 1 Fan setting during interval ventilation Selected Not selected 1 Fan run on Activated 1 Deactivated Noise reduction Activated Deactivated 1 1 Factory setting 11 3 Exiting the basic settings menu Push the control knob in While the control knob is pushed in carry out the following steps without in terruption Turn one notch ant...

Page 17: ... shop 12 2 Cleaning products You can obtain suitable cleaning products from after sales service or the online shop WARNING Risk of electric shock An ingress of moisture can cause an electric shock Before cleaning pull out the mains plug or switch off the fuse in the fuse box Do not use steam or high pressure cleaners to clean the appliance WARNING Risk of burns The appliance becomes hot during ope...

Page 18: ...dour filters bind odorous substances in air recircula tion mode Regularly replaced odour filters guarantee a high level of odour removal The odour filter of the remote fan unit must be replaced at regular intervals The saturation indicator on your ap pliance will tell you how frequently this needs to be done The odour filter provided cannot be cleaned or regenerated The regenerable odour filter is...

Page 19: ...ease filter by hand Page 17 After the appliance has been switched off the illuminated ring flashes white rapidly six times The odour filter in the remote fan unit is saturated Change the odour filter in the remote fan unit Page 18 The fan continues to run after the appli ance has been switched off The illu minated ring flashes slowly orange The fan run on is switched on Observe the information abo...

Page 20: ...er the terms of the manufacturer s warranty the use of Customer Service is free of charge Detailed information on the warranty period and terms of warranty in your country is available from our after sales service your retailer or on our website If you contact Customer Service you will require the product number E Nr and the production number FD of your appliance The contact details for Customer S...

Page 21: ...laration of Conformity can be found on line at www gaggenau com gb among the additional documents on the product page for your appliance 1 Only applies to Great Britain 2 4 GHz band 2400 2483 5 MHz Max 100 mW 5 GHz band 5150 5350 MHz 5470 5725 MHz Max 100 mW BE BG CZ DK DE EE IE EL ES FR HR IT CY LI LV LT LU HU MT NL AT PL PT RO SI SK FI SE NO CH TR IS UK NI 5 GHz WLAN Wi Fi For indoor use only AL...

Page 22: ... pressure Toxic gases from the flue or the extraction shaft are sucked back into the living space Always ensure adequate fresh air in the room if the appliance is being operated in exhaust air mode at the same time as a room air dependent heat producing appli ance is being operated It is only possible to safely operate the ap pliance if the pressure in the room in which the heating appliance is in...

Page 23: ...ave sharp edges Wear protective gloves Changes to the electrical or mechanical as sembly are dangerous and may lead to mal functions Do not make any changes to the electrical or mechanical assembly WARNING Risk of electric shock Sharp edged components inside the appli ance may damage the connecting cable Do not kink or trap the connecting cable If the appliance or the power cord is dam aged this i...

Page 24: ...nsate from returning fit the ex haust pipe with a 1 gradient from the appliance Flat ducts Use flat ducts with an inner cross section that corres ponds to the diameter of the round pipes Diameter of 150 mm corresponds to ap prox 177 cm Use sealing strips for different pipe diameters Do not use any flat ducts with sharp bends Round pipes Round pipes with an inner diameter of 150 mm 17 7 General inf...

Page 25: ...The connection strip is avail able as a special accessory 1 When making the cut out allow extra space for the connection strip between the appliances Observe the installation instructions for the con nection strip 2 When installing in individual cut outs ensure that at least 50 mm of material is left between the cut outs Installing the appliance flush with frameless induction hobs 1 For flush inst...

Page 26: ...ons 2 If the panel is more than 23 mm thick cut out the rear of the front panel for the retaining plate 3 Note the position of the control knob 4 After making the cut outs remove any shavings 5 Seal the cut surfaces so that they are heat resistant and waterproof Installing the control knob 1 Hold the retaining plate in place against the rear of the control panel 2 Use 2 screws to secure the retain...

Page 27: ...secure all connection cables after installation bend the lugs on the retaining plate Preparing the appliance Use 4 nuts to screw the exhaust air elbow tightly to the appliance Installing the appliance Requirement Observe the installation sequence First install the downdraft ventilation in the cut out in the worktop Then install the other appliances 1 Insert the connection strip into the cut out in...

Page 28: ...e 4 Leave the silicone adhesive to dry for at least 24 hours The drying time depends on the ambient temperat ure 5 Do not operate the appliance until the silicone has dried completely Connecting the appliance Requirement The control knob is turned to the zero setting 1 Use the control cable to connect the external re mote fan unit and the downdraft ventilation Ensure that the plug engages with a c...

Page 29: ...ian may work on the connection for the window contact switch in accordance with the country specific requirements and standards Observe the installation instructions provided with the window contact switch The window contact switch can be flush mounted or surface mounted The window contact switch AA400510 is available as an accessory Observe the installation instructions provided with the window c...

Page 30: ......

Page 31: ......

Page 32: ...34 81739 München GERMANY www gaggenau com 9001798616 9001798616 en 021027 Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolverton Milton Keynes MK12 5PT United Kingdom ...

Reviews: