background image

8

Caution:

Avoid sharp and caustic cleaning agents as well as
brushes and abrasive cleaners.

The stainless steel frontages

must only be

cleaned with a soft cloth.
Do not use any abrasive sponges either. Use
commercially available window cleaner and apply it
to a soft, moist cloth. Do not spray it onto the switch
panel.

Clean the 

ventilation grille

with a moist cloth 

and detergent solution. You should not clean the
ventilation grille in a dishwasher because spots 
may appear on the ventilation grille.

Grease filter cleaning

You can clean the metal grease filters in a
dishwasher at a maximum temperature of 65 °C /
150 °F. Place the grease filter in the dishwasher with
the opening pointing down to ensure that no food
remainders will stay on it.

Proceed as follows: 

(fig. 8)

– Detach the ventilation grille.
– Turn up the two retaining wires and detach the

grease filter from the appliance.

Insert in the reverse order.

The appliance must be disconnected from the
power supply during all repair work.

If the appliance does not function correctly, check
the fuses first.
If the power supply is functioning correctly, but your
appliance still does not work, please contact your

Gaggenau dealer

who will provide you with the

address and telephone number of your nearest
manufacturer’s authorized service agent or contact

Gaggenau USA on (800) 828-9165.

Specify the

appliance type (see rating plate).

4. Cleaning and care

5. Maintenance

2

Repairs 

must only be carried out by 

authorised

specialists

, thus ensuring the safety of the

appliance. Improper tampering will render all
warranty claims null and void.

Fig. 8

The 

grease filters

must be cleaned on a regular

basis (at the latest after 30 hours of operation).

Overgreased filters are a fire risk!

All manuals and user guides at all-guides.com

Summary of Contents for VL040-707

Page 1: ...Operating and assembly instructions VL 040 041 707 Hob ventilator 0 1 2 All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...r your safety Page 4 1 2 Operating for the first time Page 5 2 Structure and operating principle Page 6 2 1 Structure of the appliance Page 6 2 2 Accessories Page 6 3 Operation Page 7 4 Cleaning and c...

Page 3: ...nstructions contain important notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your per...

Page 4: ...en cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropri...

Page 5: ...this remove the mains plug or actuate the corresponding fuse If the mains plug is not accessible the appliance must be deenergised by means of the domestic installation fuse In the event of malfunctio...

Page 6: ...as your operating and assembly instructions You need the rating plate for possible damage and warranty cases Remove the packaging from the appliance and dispose of it properly Pay attention to the fac...

Page 7: ...tion extraction connection Special accessories AS 070 000 connection piece for extension during assembly fig 4 VV 200 000 connecting trim RV 050 150 bifurcated pipe for joining 2 x DN 125 into DN 150...

Page 8: ...hob ventilators That is to say if you set the control knob to level 1 both hob ventilators are operated at level 1 Switching on Turn the control knob to the right to the position you require 0 2 Swit...

Page 9: ...tilation grille Turn up the two retaining wires and detach the grease filter from the appliance Insert in the reverse order The appliance must be disconnected from the power supply during all repair w...

Page 10: ...fety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning ASHRAE and the local code authorities c...

Page 11: ...es not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall...

Page 12: ...nward Proceed as follows to establish a blow out opening at the side Undo all 5 screws on the connection piece and detach the connection piece Undo the screws of the side cover Screw the connection pi...

Page 13: ...in the screw Connect the hob ventilator to the fan module by means of the 4 pole plug Pay particular attention to ensuring that the exhaust air ducts are kept as short as possible the pipes are not l...

Page 14: ...3 6027 93ind02 en 03 03 SK 13 All manuals and user guides at all guides com...

Page 15: ...TINGTON BEACH CA 92649 USA Y 800 828 9165 FAX 714 901 0979 www gaggenau usa com GAGGENAU HAUSGER TE GMBH P O BOX 10 02 50 80076 M NCHEN GERMANY Y 089 45 90 03 FAX 089 45 90 23 47 All manuals and user...

Reviews: