Operation
Before first use
Bear in mind the following instructions before using the
appliance for the first time:
Thoroughly clean the appliance and accessories.
Turning on
For extraction, there are three ventilator settings and an
Intensive mode
Ž
available.
1
Open the dampers.
Note:
At least one damper must be open before the
fan will switch on.
2
Push the control knob in and turn it clockwise to the
required ventilator setting.
The illuminated ring behind the control knob will
light up.
Intensive mode
When combined with AA 490 111, the Intensive mode
will run for six minutes (when combined with
AA 490 110, it will be ten minutes). Once this time has
elapsed, the ventilation system automatically switches
back to ventilator setting 3.
The illuminated ring behind the control knob flashes
while the control knob is in the
Ž
Intensive mode
position after the Intensive mode has run and while at
least one ventilation element is open.
Turning off
1
Turn the control knob to the 0 position.
2
Close the dampers.
Run-on function
Ideal for ventilating the kitchen after cooking has
finished. The run-on function is only available in Level 2.
1
Open the dampers.
Note:
At least one damper must be open before the
fan will switch on.
2
Push the control knob in and turn it
counterclockwise to the run-on function
ž
.
The illuminated ring behind the control knob will
flash.
When combined with AA 490 111, the run-on time will
be six minutes (when combined with AA 490 110, it will
be ten minutes).
Once the run-on time has elapsed, the ventilation
system will switch off automatically.