![Gaggenau VI422115 User Manual And Installation Instructions Download Page 36](http://html1.mh-extra.com/html/gaggenau/vi422115/vi422115_user-manual-and-installation-instructions_3329233036.webp)
en
Installation instructions
36
25.12 Connecting the control knob to the
connection cables
1.
Connect all of the control knobs to the enclosed
connection cables.
The two connectors on the control knob are
identical.
2.
Ensure that the plugs snap into place in the con-
nectors.
3.
Connect the central control knobs to one of the
longer connection cables.
4.
After installation, check that all of the plug connec-
tions are seated correctly.
5.
To secure all connection cables after installation,
bend the mounting brackets on the retaining plates.
25.13 Connecting connection cables to the
appliance
ATTENTION!
Heat may damage the appliance's connection cables.
▶
Ensure that the connection cables do not touch any
hot parts of the hob or oven.
▶
Install an intermediate floor so that the connection
cables are no longer accessible after the hob has
been installed.
1.
Connect the connection cable for any of the control
knobs to the appliance's socket.
2.
Ensure that the plug engages in the socket.
25.14 Installing the appliance
WARNING ‒ Risk of electric shock!
If the insulation of the power cord is damaged, this is
dangerous.
▶
Never let the power cord come into contact with hot
appliance parts or heat sources.
▶
Never let the power cord come into contact with
sharp points or edges.
▶
Never kink, crush or modify the power cord.
1.
Keeping the appliance level, insert it into the unit
cut-out.
2.
If the oven is a built-under type, route the mains
connection cable along the rear corners of the oven
to the mains socket.
25.15 Establishing the power supply
1.
Observe the connection data on the rating plate.
2.
Connect the cable to the mains socket in accord-
ance with the figure.
3.
Note the colours of the cables.
– BN: Brown
– BU: Blue
– GN/YE: Green and yellow