13
7.1 Important notes
Please observe the
safety notes
and the
important notes
(Chapter 1).
The installer
is responsible for perfect functioning
of the appliance at its installation location.
He must explain the operating principle to the user
with reference to the operating instructions and
must show how to switch of the electricity and gas
whenever required.
Caution:
Before connecting the appliance, please check
whether the
local connection conditions
such as
the gas type, gas pressure and mains voltage and
the appliance settings are correct. Refer to the
adhesive label on the gas connection or the
rating
plate
for the necessary information. This gas hob
conforms to the categories that are specified on the
rating plate. The rating plate can be found on the
appliance and additionally on the enclosed adden-
dum sheet. By replacing nozzles, it is possible to
set the appliance to any gas listed on the rating
plate.
If the data should not agree, the appliance must
be set to the required gas type and the available
pressure.
As this gas hob is not intended for connection to an
exhaust gas system, pay attention to the applicable
installation conditions.
Note on ventilation:
To ensure good combustion, the room in which this
appliance is installed must have a minimum volume
of 10 m
3
and a door that opens out to outdoors or a
window that can be opened.
Warning:
This appliance shall only be installed by an
authorized person.
The appliance shall be installed in accordance with
the manufacturer’s Installation Instructions, local
Gas Fitting Regulations, Municipal Building Codes,
the A.G. A. Installation Code for Gas Burning
Appliances, the S.A.A. Wiring Code, local Electric
Authority Regulations and any other statutory
regulations.
The appliance
may be installed in kitchen
combinations made of wood or similar combustible
materials without taking additional measures.
A minimum clearance of 260 mm
from the
periphery of the burner to a rear or side horizontal
combustible surface must be observed.
If clearance is less than 260 mm
then that
surface must be protected in accordance with
clause 5.12.1.2 of AG601-98.
Overhead clearances
Rangehoods and exhaust fans shall be installed in
accordance with the manufacturers instructions.
However, in no case shall the clearance between
the highest part of the burner and the underside of
the rangehood be less than
600 mm
or for a
overhead exhaust fan,
750 mm
.
After unpacking, check the appliance for any
transportation damage and report this immediately
to the transportation company.
Technical modifications reserved.
7. Assembly instructions