Installation and connection
en
9
¡
Equipment and accessories
1
¡
Installation material
¡
Installation instructions
¡
User manual
¡
Customer service directory
¡
Warranty enclosure
2
¡
Energy label
¡
Information on energy consump-
tion and noises
4.2 Criteria for the installation
location
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
▶
Only install the appliance in a
space with a volume of at least
1 m
3
per 8 g refrigerant. The
volume of refrigerant is indicated
on the rating plate.
4
The weight of the appliance ex works
may be up to 35 kg depending on
the model.
The subfloor must be sufficiently
stable to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate.
4
Climate
class
Permitted room tem-
perature
SN
10 °C to 32 °C
N
16 °C to 32 °C
ST
16 °C to 38 °C
T
16 °C to 43 °C
The appliance is fully functional within
the permitted room temperature.
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5 °C.
Built-under
Attachment under certain worktops,
e.g. stone, glass or stainless steel, is
frequently not possible. You can or-
der accessories from customer ser-
vice for installation on the side walls.
→
4.3 Installing the appliance
▶
Install the appliance in accordance
with the enclosed installation in-
structions.
4.4 Preparing the appliance
for the first time
1.
Remove the informative material.
2.
Remove the protective foil and
transit bolts, e.g. remove the ad-
hesive strips and carton.
3.
Clean the appliance for the first
time. →
1
Depending on the appliance specifications
2
Not in all countries