![Gaggenau KG 260 CA Operating And Assembly Instructions Manual Download Page 13](http://html.mh-extra.com/html/gaggenau/kg-260-ca/kg-260-ca_operating-and-assembly-instructions-manual_556011013.webp)
12
Technical data (gas)
Burners: Normal
burner
Full burning
6500 BTU (1.90 kW)
Low burning
< 1400 BTU (0.41 kW)
High-intensity burner
Full burning
9500 BTU (2.8 kW)
Low burning
< 1900 BTU (0.56 kW)
Gas connection:
R 1/2’’ union nut for R 1/2’’ bracket to DIN 1999,
conical-cylindrical
Technical data, gas
Technical data (electrical)
Rated consumption
0.8 W
Voltage
AC 120 V
Frequency
60 Hz
Technical modifications reserved.
6. Technical data / Settings table
Countries
US
US
CA
CA
Gas family
Natural gas
Propane gas
Gas type
A
E
Pressure
6” W.C. (1.5 kPa)
10” W.C. (2.5 kPa)
A burner, full burning
0.94
0.74
A burner, low burning
0.49
0.36
B burner, full burning
1.28
0.87
B burner, low burning
0.58
0.42
∑ Power
32 000 BTU (9.4 kW)
32 000 BTU (9.4 kW)
∑ Consumption
0.9 m
3
/h