Prepare built-in units

Important:

 The power outlet must be located outside the 

built-in cut-out.

Make sure there is adequate aeration. To do this, 
remove the rear panel or cut out an opening of 19

11

16

" x 

15

3

4

" (500 x 400 mm). There must be a gap of at least 

1

3

8

" (35 mm) between the wall and base of the unit or 

the rear panel of the unit situated above. The ventilation 
slots and intake openings must not be covered. Also 
follow the installation instructions for the appliance 
situated above or below. If installing the appliance 
above a warming drawer, the height of the recess must 
be 23

1

4

" (590 mm). If the appliance is installed directly 

under a décor panel, ensure that there is a ventilation 
slot of at least 31 square inches (200 cm

2

). The 

appliance should not be installed too high, approx. 37

3

8

(950 mm), to ensure that function parts, e.g. container 
or brewing unit, can be removed without difficulty. The 
display should not be located above eye level to ensure 
legibility.

Protect the appliance against freezing or it will be 
damaged.

9

CAUTION

Installation must always be performed by two 
persons.

Installation preparation

1

Unpack all the parts and check for any damage in 
transit. Do not operate a damaged appliance. 

Fig. 1

2

Take note of the installation dimensions of the 
particular model.

 Fig. 2

 

Important:

 Two opening angles can be selected for 

the door. Depending on the opening angle 
required, the mounting distance to the wall should 
be observed before installation.

Opening angle approx. 110° (delivery status)
= mounting distance to the wall at least 13

3

4

(350 mm).

Opening angle approx. 155°
= mounting distance to the wall at least 25

9

/

16

(650 mm). 
For an opening angle of 155°, remove both the 
restrictors at the top and bottom of the hinge.

3

Position the assembly bracket 

(c)

 according to the 

measurement stated in the image and fasten it with 
2 fastening screws 

(f)

 to the cabinet as shown. The 

assembly bracket must be positioned at the base of 
the unit and the wall such that no gap is present. 

Fig. 3

4

Fasten the transformer mount 

(d)

 with 2 screws 

(f) 

in the middle. 

Fig. 4

5

Insert the transformer in the mount. The 
connections to both lines must point to the left. 

Fig. 5

Note: 

When positioning the transformer 

(k)

 and 

pushing in the appliance, do not trap the lines. 
The transformer 

(k)

 is not allowed to touch the 

appliance and the back wall of the cupboard. 

6

Set the main switch 

(U)

 to [

Û

] on the appliance. 

Fig. 6

Note: 

The appliance can  be directly connected to 

the home network. To do this, insert a LAN cable 
(not included in scope of supply) into the appliance.

Important:

 

Fig. 7

The distance between the appliance and the rear 
wall must be at least 13

15

16

" (100 mm). 

The power cord or the LAN cable must not be 
kinked or crushed. 

A recess of 4

23

32

" (120 mm) x 11

13

16

" (300 mm) is 

required for water inlet hose and drain water 
hose. If required, adjust the furniture base 
accordingly.

The hose guide 

(l)

 should end at the edge of the 

furniture base. 

The connecting hose guide 

(l)

 should be 

adapted to the edge of the furniture if necessary. 

7

Screw the hose guide 

(l)

 with the fastening screw 

(i)

 to the rear wall of the appliance. 

Fig. 8

8

Insert the drain water hose in the hose guide 

(l)

.

Summary of Contents for CM470712/01

Page 1: ...Gaggenau Installation instructions 10 Notice de montage 19 Instrucciones de instalaci n 28 CM470712 Fully Automatic Espresso Machine Machine caf enti rement automatique Cafetera autom tica...

Page 2: ...2 D PP PP PP PP F E G H PP PP PP PP LQ LQ LQ LQ I J K M L O P Q R 8 N PP...

Page 3: ...3 PLQ PP PP PP PP PP PLQ PP PLQ PP PLQ PP PP PP F I I G PP N...

Page 4: ...4 PP PP 9 PLQ PLQ PP...

Page 5: ...5 PLQ PP PD PP PD PLQ 9...

Page 6: ...6 PLQ PP PLQ 9 PD PLQ PLQ PP R PD PP O IO R PLQ...

Page 7: ...7 PP PP PP PP PP PP H LQ LQ LQ LQ H H O OO...

Page 8: ...8 Q K I I I J J M M R 9...

Page 9: ...9 L...

Page 10: ...ccur as a result of non observance of this warning 9 CAUTION This indicates that minor or moderate injuries may occur as a result of non observance of this warning NOTICE This indicates that damage to...

Page 11: ...ith local and national regulations NOTICE Protect your Coffeemaker and hoses against freezing or it will be damaged WARNING To reduce risk of fire and electric shock Installation Do not mount any appl...

Page 12: ...be installed directly above Gaggenau Warming Drawer Model WS461 CAUTION To avoid the risk of suffocation Do not allow children to play with packaging material Store small parts safely as they can be a...

Page 13: ...nected only by an approved technician The water quality must comply with the drinking water regulations of the individual country in which the appliance is operated The connection to the domestic wate...

Page 14: ...g angle approx 110 delivery status mounting distance to the wall at least 133 4 350 mm Opening angle approx 155 mounting distance to the wall at least 259 16 650 mm For an opening angle of 155 remove...

Page 15: ...Remove if necessary 1 Position the hose with a continuous slope to avoid a bend Fig 10 I 2 Shorten the hose if necessary Fig 10 II 3 Place the hose clamp for the adapter and the adapter on the waste...

Page 16: ...tely Fig 13 If the water fails to drain off check installation of the hose and the waste water connection according to the information in these installation instructions 3 Check that the appliance is...

Page 17: ...p should be cleaned regularly 1 Turn off the tap 2 Unscrew the water inlet hose with the AquaStop from the tap 3 Clean the filter with a small brush Important Do not remove the filter under any circum...

Page 18: ...tomers reasonable and verifiable damages 2 A condition of all warranty claims is the appliance with Aqua Stop must have been installed and connected correctly in accordance with all instructions this...

Page 19: ...tra ner des blessures graves voire la mort 9 ATTENTION Ceci indique que le non respect de cet avertissement peut entra ner des blessures l g res ou de gravit moyenne AVIS Ceci indique que la non confo...

Page 20: ...imentation en eau conform ment aux r glements locaux et nationaux AVIS Prot ger la machine caf et vos tuyaux du gel afin de les conserver en bon tat AVERTISSEMENT Pour r duire le risque de choc lectri...

Page 21: ...N Pour viter tout risque d touffement Ne jamais laisser les enfants jouer avec le mat riel d emballage Conserver les pi ces de petite taille dans un endroit s r car elles posent un risque d touffement...

Page 22: ...technicien autoris uniquement La qualit de l eau doit r pondre aux normes sur l eau potable propres au pays dans lequel l appareil est utilis Le raccordement au syst me d eau domestique ainsi que tou...

Page 23: ...les d ouverture de la porte En fonction de l angle d ouverture souhait il faudra pr voir une distance de montage suffisante avec le mur avant l installation Angle d ouverture d env 110 tat la livraiso...

Page 24: ...est pas recouvert ce qui emp cherait l eau d y circuler Retirer le capuchon si n cessaire 1 Positionner le tuyau en pente continue afin d viter les courbures Fig 10 I 2 Raccourcir le tuyau si n cessa...

Page 25: ...eil dans l unit jusqu ce qu il s encliquette Important la prise doit tre facilement accessible m me une fois l appareil install 2 V rifier l vacuation d eau Pour ce faire verser lentement environ 0 5...

Page 26: ...puchon X en place et le fixer avec les deux vis de fixation noires i Fig 18 8 Remettre en place le plateau d gouttage Y et le tiroir d accessoires Z et fermer la porte de l appareil Fig 19 Erreur de c...

Page 27: ...les du client 2 Toutes les revendications de garantie ont pour condition pr alable que l appareil dot de l Aqua Stop soit install et branch correctement selon nos instructions cela inclut galement une...

Page 28: ...graves o incluso la muerte si no se cumple con esta advertencia 9 ATENCION Esto indica que pueden producirse heridas leves o moderadas si no se cumple con esta advertencia AVISO Esto indica que puede...

Page 29: ...a la congelaci n o se da ar n ADVERTENCIA Para reducir el riesgo de incendio y descarga el ctrica Instalaci n No instalar ning n aparato con conexi n fija a toma de agua sobre la cafetera autom tica C...

Page 30: ...con combinaciones no aprobadas Nota La unidad puede instalarse directamente encima del caj n calientaplatos Gaggenau modelo WS461 ATENCION Para evitar riesgo de sofocaci n No dejar que los ni os juegu...

Page 31: ...lifornia Lista de partes incluidas iQFHU GDxR UHSURGXFWLYR ZZZ 3 DUQLQJV FD JRY 9 57 1 1 9 578 352326 1 9 57 1 67 2 251 a Cafetera autom tica b Instrucciones de montaje c ngulo de montaje d Base del t...

Page 32: ...rior del aparato La manguera de desag e no debe ser prolongada Si la ubicaci n de la instalaci n del aparato est demasiado alejada del punto principal de desag e sif n el sistema de desag e instalaci...

Page 33: ...s dos topes superior e inferior de la bisagra 3 Posicionar la escuadra de montaje c de conformidad con la medida indicada en la imagen y atornillarla en el armario mediante 2 tornillos de fijaci n f c...

Page 34: ...o mediante un sif n de embudo Importante El sif n debe tener una conexi n adecuada La manguera de desag e no debe estar m s alta que el extremo inferior del aparato en ning n punto Verificar que la ma...

Page 35: ...del gabinete hasta que se escuche un chasquido Importante El enchufe debe permanecer f cilmente accesible en todo momento despu s de haber instalado el aparato 2 Controlar el drenaje del agua Para ell...

Page 36: ...dos tornillos de sujeci n negros i Fig 18 8 Volver a colocar la bandeja de goteo Y y el caj n de accesorios Z y cerrar la puerta del aparato Fig 19 Fallo en el flujo de agua El filtro en el AquaStop d...

Page 37: ...ompensar a los clientes por da os razonables y verificables 2 Para la aplicaci n de la garant a es imprescindible que el electrodom stico con Aqua Stop haya sido instalado y conectado correctamente de...

Page 38: ......

Page 39: ......

Page 40: ...Corporation 1901 Main Street Suite 600 Irvine CA 92614 1 877 442 4436 www gaggenau com us 2020 BSH Home Appliances Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen GERMANY 8001214777 8001214...

Reviews: