en-us
Conversion to LP gas
12
4.9 Checking the installation
Check if your unit is working properly after you have com-
pleted the installation steps.
WARNING
Before you turn on power supply, make sure all controls
are in the OFF position.
Requirement: The burner caps are properly positioned.
1.
Verify that the electric igniters are working.
2.
Check the flame characteristics.
The flame should be blue with a minimal yellow tip on
the outer cone.
Flame characteristics
The color of the flame tells you if the gas supply is properly adjusted.
Note: Allow the appliance to operate for 4 to 5 minutes before evaluating the flame. Some yellow streaking is normal dur-
ing the initial startup.
Flame
Image
Measure
Completely or mostly
yellow
Verify that the regulator is set for the correct fuel. Retest af-
ter adjustment.
Yellow tips on outer
cone
Normal for LP gas
Soft blue
Normal for natural gas
Conversion to LP gas
5 Conversion to LP gas
Conversion to LP gas
Your appliance is equipped for use with natural gas on de-
livery. It can be changed to LP gas supply.
The components required for conversion to LP Gas are
contained in the conversion kit included with this appli-
ance, or are available from Customer Service.
Only a licensed specialist is authorized to switch the appli-
ance to another gas type.
Before carrying out the conversion, turn off the electricity
and gas supply.
5.1 Converting the pressure regulator
1.
Locate the pressure regulator on the bottom right end of
the appliance.