Outlet Area
The outlet can be located anywhere within the shaded
area. Anywhere within the shaded area the minimal
distance between the appliance and the wall is 1¾ in
(45 mm).
Removing Packaging
NOTICE:
To prevent damage to your floor keep the
unit in its packaging base until ready to be placed in
the cabinet opening. Do not slide the unit across the
flooring.
Different models use different packaging materials.
Actual brackets may look differently. Bracket remains
in packaging base.
1
Cut straps on outside of box.
2
Remove cardboard box.
3
Remove all top and side cardboard and Styrofoam
braces.
4
Place microwave oven in front of cabinets where it
is to be installed.
Install Appliance
Note:
The appliance is heavy. It is advisable to install
it with a second person.
NOTICE:
Before installing the appliance, be sure to
verify the cabinet dimensions and electrical
connections.
Electrical Installation
9
WARNING
The electrical connection of the appliance must
be carried out by a qualified electrician in
accordance with local and regional safety
codes.
9
WARNING
This product will only operate when L1 and L2
are powered up simultaneously. If this does not
occur, then an E300 error will be displayed. This
appliance should be installed with a branch
circuit breaker to allow L1 and L2 to be powered
up simultaneously.
Install a suitable conduit box (not included). The
conduit connector must be used to correctly attach the
conduit to the junction box.
All 4 wires must be connected, regardless if a 3 or
4 wire connection is used.
PP
ʌ¼ʚ
ê
PP
ʌ¼ʚ
ê
Model
Connection
Circuit
Requirements
BM 450 710
BM 451 710
BM 484 710
BM 485 710
4 wire conduit
cable
208 V,
60 Hz
or
240 V,
60 Hz
20 Amps
20 Amps