background image

en 

Installation instructions

16

Grease deposits in the grease filter may catch
fire.

Never work with naked flames close to the
appliance (e.g. flambéing).

Do not install the appliance near a heat-
producing appliance for solid fuel (e.g.
wood or coal) unless a closed, non-remov-
able cover is available. There must be no
flying sparks.

WARNING ‒ Risk of injury!

Components inside the appliance may have
sharp edges.

Wear protective gloves.

The appliance may fall down if it has not been
properly fastened in place.

All fastening components must be fixed
firmly and securely in place.

Risk of injury from glass splinters.

Protect the filter cover against impact.

Do not drop the filter cover.

Wear protective goggles during installation.

The appliance is heavy.

The appliance must not be fitted directly
onto plasterboard or similar lightweight ma-
terials.

To ensure correct installation, you must use
a material which is sufficiently stable and
suitable for both the structural conditions
and the weight of the appliance.

Changes to the electrical or mechanical as-
sembly are dangerous and may lead to mal-
functions.

Do not make any changes to the electrical
or mechanical assembly.

The filter cover may swing out.

Open the filter cover slowly.

Take hold of the filter cover after opening
until it no longer swings out.

Close the filter cover slowly.

Risk of injury when opening and closing the
hinges.

Keep your hands away from the hinges.

WARNING ‒ Risk of electric shock!

Sharp-edged components inside the appli-
ance may damage the connecting cable.

Do not kink or trap the connecting cable.

If the appliance or the power cord is dam-
aged, this is dangerous.

Never operate a damaged appliance.

Never pull on the power cord to unplug the
appliance. Always unplug the appliance at
the mains.

If the appliance or the power cord is dam-
aged, immediately unplug the power cord
or switch off the fuse in the fuse box.

Call customer services. → 

Page 12

Incorrect repairs are dangerous.

Repairs to the appliance should only be
carried out by trained specialist staff.

Only use genuine spare parts when repair-
ing the appliance.

If the power cord of this appliance is dam-
aged, it must be replaced by trained spe-
cialist staff.

Incorrect installation is dangerous.

Connect and operate the appliance only in
accordance with the specifications on the
rating plate.

Connect the appliance to a power supply
with alternating current only via a properly
installed socket with earthing.

The protective conductor system of the do-
mestic electrical installation must be prop-
erly installed.

Never equip the appliance with an external
switching device, e.g. a timer or remote
control.

When the appliance is installed, the mains
plug of the power cord must be freely ac-
cessible. If free access is not possible, an
all-pole isolating switch must be installed in
the permanent electrical installation accord-
ing to the conditions of Overvoltage Cat-
egory III and according to the installation
regulations.

When installing the appliance, check that
the power cable is not trapped or dam-
aged.

Summary of Contents for AW250192

Page 1: ...en User manual and installation instructions AW250192 AW251192 AW253192 AW250172 AW251172 AW253172 AW270192 AW271192 AW273192 Gaggenau...

Page 2: ...suring that the appliance works perfectly at its installation location Only use this appliance For extracting cooking vapour In private households and in enclosed spaces in a domestic environment Up t...

Page 3: ...e is operated exclusively in circulat ing air mode WARNING Risk of fire Fatty deposits in the grease filters may catch fire Never operate the appliance without a grease filter Clean the grease filters...

Page 4: ...airs are dangerous Repairs to the appliance should only be carried out by trained specialist staff Only use genuine spare parts when repair ing the appliance If the power cord of this appliance is dam...

Page 5: ...the lighting if you no longer require it The lighting does not consume any energy Clean or replace the filters at regular intervals The effectiveness of the filter is retained Put the cooking lid on T...

Page 6: ...5 Switching off intensive mode Press 6 6 Switching on intermittent ventilation With intermittent ventilation the appliance switches the ventilation on and off at regular intervals Press a The applian...

Page 7: ...ng the odour filter the saturation indicator can be reset Requirements After the appliance has been switched off and 1 appears on the display for the grease filter After the appliance has been switche...

Page 8: ...ing the connection To reset the saved connections to the Wi Fi and to Home Connect press and hold and at the same time until goes out 7 3 Software update Your appliance s software can be updated using...

Page 9: ...ll and you are no longer able to use Home Connect Requirements The appliance is switched off All connections to the Wi Fi or other appliances have been reset Resetting the connection Page 8 1 Note Ref...

Page 10: ...nium using a soft cloth and glass cleaner Clean plastic using a soft cloth and glass cleaner Clean glass using a soft cloth and glass cleaner 3 Dry with a soft cloth 4 Apply a thin layer of the stainl...

Page 11: ...e cooking va pour Regularly cleaned grease filters guarantee a high level of grease removal WARNING Risk of fire Fatty deposits in the grease filters may catch fire Clean the grease filters regularly...

Page 12: ...can be obtained from Customer Service for a period of at least 10 years from the date on which your appliance was placed on the market within the European Economic Area Note Under the terms of the man...

Page 13: ...tailed RED Declaration of Conformity can be found online at www gaggenau com among the additional documents on the product page for your appliance Hereby Gaggenau Hausger te GmbH declares that the app...

Page 14: ...the appliance 15 3 Appliance dimensions You will find the dimensions of the appliance here 15 4 Installation recommendation We recommend fitting the appliance such that the lower edge of the glass sc...

Page 15: ...ble to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the ap pliance is operated exclusively in circulat in...

Page 16: ...es WARNING Risk of electric shock Sharp edged components inside the appli ance may damage the connecting cable Do not kink or trap the connecting cable If the appliance or the power cord is dam aged t...

Page 17: ...ating air mode If you operate the appliance in circulating air mode the enclosed odour filters must be installed For operation in circulating air mode the installation of the flue cover is optional 15...

Page 18: ...as required 4 Tighten the safety screws When you install a flue cover install the bracket and hold it in place while screwing it in tight Piping Air extraction mode If you operate the appliance in ai...

Page 19: ...uct to the wall 2 To separate the flue ducts remove the adhesive tape or the flue duct from the protective packaging 3 Remove any protective foil from both flue ducts 4 Note The slots on the flue duct...

Page 20: ...e 34 81739 M nchen GERMANY www gaggenau com 9001640928 9001640928 en 010910 Valid within Great Britain Imported to Great Britain by BSH Home Appliances Ltd Grand Union House Old Wolverton Road Wolvert...