Gaggenau AW 543-120 Operating And Assembly Instructions Manual Download Page 8

6

3. Operation

The AW 540/541-190 is 90 cm wide, and the 
AW 540/541/542/543-120 is 120 cm wide. Operation
of both extractor hoods is identical.
After they have been pressed, all functions
selection keys except 

0

(“Motor off”) are backlit in

green.

Light

The lighting can be switched on or off, regardless

of whether the wall extractor is in operation, by
pressing the 

key (see Fig. 4).

When you briefly press the 

key, the lighting is

increased up to the maximum level.

You can dim the lighting to the required level by
keeping the 

key pressed.

F

an levels

Three fan speeds and one intensive speed are

available (see Fig. 5). You set the fan level required
for each respective cooking situation by pressing
the function selector keys 

1, 2, 3

or 

Int

.

Fig. 4

Fig.  5

or

or

or

Summary of Contents for AW 543-120

Page 1: ...Operating and Assembly Instructions AW 540 190 120 AW 541 190 120 AW 542 120 AW 543 120 Extractor Hood...

Page 2: ......

Page 3: ...Page 3 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly...

Page 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Page 5: ...nce Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operatio...

Page 6: ...there are accessories in the packaging Keep packaging elements e g plastic foil styrofoam parts out of the reach of children Thoroughly clean the appliance before using it for the first time see chap...

Page 7: ...4 m LK 011 022 for ceiling heights of 2 64 3 02 m Installation accessories for circulating air mode Stainless steel design ventilation duct LK 010 112 for ceiling heights of 2 36 2 64 m LK 010 122 for...

Page 8: ...d on or off regardless of whether the wall extractor is in operation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the ligh...

Page 9: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Page 10: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Page 11: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Page 12: ...soft cloth and mild detergent solution Do not use any strong caustic or abrasive cleaning agents Do not use any abrasive sponges or brushes either Clean the stainless steel extractor hood AW 540 AW 5...

Page 13: ...tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use...

Page 14: ...bottom edge of the wall hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the wall hood is 700 mm for gas appliances The hood ca...

Page 15: ...The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Sta...

Page 16: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction...

Page 17: ...ix the two hooks d with the countersunk screws c Make sure that the hooks lie flatly on the wall In certain circumstances you may have to countersink the drill holes Fit the included dowels a in the o...

Page 18: ...he fastening holes on the side are at the top Put both chimney duct units onto the hood Pull the top chimney duct unit up into its final position and secure it with 2 screws on the ceiling holder Fig...

Page 19: ...lish the electrical connection Stainless steel chimney only LK 010 112 122 pull the protective film off the chimney s trims Note avoid damaging the sensitive metal surfaces Fit the top chimney duct un...

Page 20: ...GAGGENAU HAUSGER TE GMBH CARL WERY STR 34 D 81739 M NCHEN Y 089 45 90 03 FAX 089 45 90 23 47 www gaggenau com...