background image

Extractor hood
AW 280790/280720

Gaggenau Operating and installation instruction

Summary of Contents for AW 280790

Page 1: ...Extractor hood AW 280790 280720 Gaggenau Operating and installation instruction ...

Page 2: ...um settings b Always turn hood on when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Always use cookware appropriate for the size of the surface element WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING a SMOTHER FLAM...

Page 3: ...ing procedure 8 Intensive setting 9 Special functions 9 Filters and maintenance 10 Grease filters 10 Saturation indicator F 10 Activated carbon filter 11 Cleaning and care 12 Replacing the light bulbsn 13 Installation Instructions Important information 15 Prior to installation 17 Exhaust air mode 17 Circulating air mode 18 Preparing the wall 19 Electrical connection 19 Installation 20 Table of Con...

Page 4: ...cal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not ap...

Page 5: ...tracted particularly well at the front of the cooking field The Coanda effect may allow you to operate the extractor hood at a lower quieter level than you were previously accustomed to The Coanda air flow exits the top of the extractor hood s front panel Do not place any objects on the extractor hood these may disrupt the Coanda effect 5 ...

Page 6: ...ging elements out of the reach of children Thoroughly clean the appliance before using it for the first time Before operating the appliance for the first time check that the mains connection is in proper working order In the event of malfunctions first of all check the household fuses If the problem has nothing to do with the power supply please contact your specialist dealer or your local Gaggena...

Page 7: ...injury to the user Do not place any heavy objects on the appliance Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this switch off the corresponding fuse Repairs must be carried out by authorised specialists thus ensuring electrical safety No w...

Page 8: ...Light Fan follow on Intensive setting The most effective method of removing vapours produced during cooking is to Switch the ventilator ON as soon as you begin cooking Switch the ventilator OFF a few minutes after you have finished cooking Fan settings ...

Page 9: ...el running time to 3 5 or 10 minutes by simultaneously pressing the Int key and the 1 2 or 3 key and you can store this setting When delivered the appliance is set to five minutes i e the combination of the Int key and the key 2 Fan follow on Delayed shut off is possible at any level First press the required key 1 2 3 or Int and then press the key The delayed shut off time for all levels is ten mi...

Page 10: ... has not started to flash Cleaning the metal grease filters In normal operation 1 to 2 hours daily the metal grease filter must be cleaned 1 x a month The filters can be cleaned in a dishwasher It is however possible that they will become slightly discoloured The filter must be placed loosely and NOT wedged in the dishwasher Important Metal filters that are saturated with grease should not be wash...

Page 11: ...emoving and inserting the metal mesh grease filters 2 Insert the activated carbon filter 3 Insert the metal grease filters see Removing and inserting the metal grease filters Replacing the activated carbon filter During normal operation 1 to 2 hours per day the activated carbon filters should be replaced approximately 1 x year A replacement filter can be obtained from any authorized dealer see opt...

Page 12: ...isk of fire and ensures that the extractor hood continues operating at maximum efficiency 몇 Clean the operating buttons with a mild soapy solution and a soft damp cloth only Do not use stainless steel cleaner to clean the operating buttons Stainless steel surfaces Use a mild non abrasive stainless steel cleaner Clean the surface in the same direction as it has been ground and polished We recommend...

Page 13: ...l a risk of being burnt 2 Remove the metal mesh filters see Removing and inserting the metal mesh grease filters 3 Loosen the screws for the mounting rails 4 Carefully remove the glass panes 5 Remove the sockets for the fluorescent light bulbs 6 Replace the fluorescent light bulbs with new ones available commercially 36 W 840 Cool White socket 2 G 11 몇 Risk of breakage Replacing the light bulbs ...

Page 14: ... 9 Tighten the screws for the mounting rails 10 Insert the metal grease filters see Removing and inserting the metal grease filters 11 Restore the power by inserting the mains plug or switching on the fuse Note If the light does not function check that the bulbs have been inserted correctly ...

Page 15: ...xhaust air shaft or directly into the open through the outside wall It is not allowed to pass the exhaust air into a flue or exhaust air chimney that is in operation or into a shaft that is linked to the heating basement Consult the chimney sweep responsible for your district whenever you wish to pass the exhaust air into a chimney that is not in operation During the course of planning a chimney s...

Page 16: ... The extractor hood must not be installed over a solid fuel cooker a potential fire hazard e g flying sparks unless the cooker features a closed non removable cover and all national regulations are observed The smaller the gap between the extractor hood and hotplates the greater the likelihood that droplets will form on the underside of the extractor hood Additional information concerning gas cook...

Page 17: ...r coal fired heaters continuous flow heaters hot water boilers care must be taken to ensure that there is an adequate supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e ...

Page 18: ...ipes We recommend Internal diameter 6 Flat ducts must have an internal cross section that equates to that of round pipes There should be no sharp bends l 6 approx 177 cm2 If pipes have different diameters Insert sealing strip For exhaust air mode ensure that there is an adequate supply of fresh air Connecting a l 6 exhaust air pipe Mount the pipe directly onto the air outlet on the hood Circulatin...

Page 19: ...y be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed socket directly behind the chimney panelling The earthed socket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the extractor hood ensure that there is a permanently installed disconnector If it is necessary to wi...

Page 20: ...the outline of the area where the hood will be attached 몇 Ensure that the minimum distance between the hob and the extractor hood is maintained 30 for an electric hob and 30 for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 2x 5 16 ø holes for the upper fixing bracket and 2x 5 16 ø holes for the lower fixing bracket and press in wall plugs flush ...

Page 21: ...move the extractor hood Drill the 4 lower 5 16 ø fixing holes and press in the wall plugs flush with the wall 8 Attach the extractor hood and screw into position with the remaining 4 screws 9 Stick protective film over the holes of the 2 lower mounting bolts in the protective grid 10 Connect up the air outlet pipe 11 Connect the hood to the electricity supply 143 64 min 30 921 64 619 64 3 ...

Page 22: ...Insert the upper flue duct into the lower flue duct 몇 Protect the cover panels from scratches for example by laying the template used for marking the wall over the top edge of the lower section 14 Insert the complete flue duct at an angle and swivel to the rear 15 Carefully pull the upper flue duct upwards and screw the sides to the fixing bracket with 2 screws 16 Insert the grease filter refer to...

Page 23: ...23 KF001 010 ...

Page 24: ...enau 5551 McFadden Avenue Huntington Beach CA 92649 Telephone 877 4GAGGENAU USA www gaggenau usa com Gaggenau Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www gaggenau com 9000384457 EB 8810 en ...

Reviews: