16.6 Installation recommendation
We recommend fitting the appliance such that the
lower edge of the glass screen is in line with the lower
edges of the adjacent wall-hung cabinets.
B
B
Maintain the safety clearances to the hob. →
16.7 Instructions for the electrical
connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
WARNING ‒ Risk of electric shock!
It must always be possible to disconnect the appliance
from the electricity supply. The appliance must only be
connected to a protective contact socket that has been
correctly installed.
▶
The mains plug for the mains power cable must be
easily accessible after the appliance is installed.
▶
If this is not possible, an all-pole isolating switch
must be integrated into the permanent electrical in-
stallation according to the conditions of overvoltage
category III and according to the installation regula-
tions.
▶
The permanent electrical installation must only be
wired by a professional electrician. We recommend
installing a residual-current circuit breaker (RCCB)
in the appliance's power supply circuit.
Sharp-edged components inside the appliance may
damage the connecting cable.
▶
Do not kink or trap the connecting cable.
¡
The connection data can be found on the rating
plate. →
¡
The connecting cable is approx. 1.30 m long.
¡
This appliance complies with the EC interference
suppression regulations.
¡
The appliance corresponds to protection class 1.
You should therefore only use the appliance with a
protective earth connection.
¡
Do not connect the appliance to the power supply
during installation.
¡
Ensure that the protection against contact is guaran-
teed during installation.
16.8 Information on the installation situation
¡
Install this appliance on the kitchen wall.
¡
To install additional special accessory parts, ob-
serve the enclosed installation instructions.
¡
The appliance must be installed with no more than
one side directly next to a high-sided unit or a wall.
The distance between the appliance and wall or
high-sided unit must be at least 50 mm.
¡
The width of the extractor hood must correspond at
least with the width of the hob.
¡
To optimally detect the cooking vapours, install the
appliance in the middle of the hob.
Air extraction mode
¡
If you operate the appliance in air extraction mode,
a flue cover must be installed.
Circulating-air mode
¡
If you operate the appliance in circulating-air mode,
the enclosed odour filters must be installed.
¡
For operation in circulating-air mode, the installation
of the flue cover is optional.
16.9 Installation
Checking the wall
1.
Check whether the wall is horizontal and adequately
load-bearing.
The maximum weight of the appliance is 40 kg.
2.
Drill the hole depth in accordance with the length of
the screws.
3.
Use the enclosed screws and wall plugs.
The enclosed screws and wall plugs are suitable for
use with solid brickwork. Use suitable fixing material
for other structures, e.g. plasterboard, porous con-
crete, poroton bricks.
4.
Install the appliance with a fixing material which is
sufficiently stable and has been adjusted accord-
ingly for both the structural conditions and the
weight of the appliance.
5.
Check the cut-out area for existing cables of other
appliances.
Preparing the wall
1.
Observe the information on the installation situation.
→
2.
Ensure that there are no electrical wires, gas pipes
or water pipes in the area where holes are to be
drilled.
3.
Cover the hob to prevent damage.
4.
Determine the position of the extractor hood and
lightly mark where the lower edge of the appliance
should be on the wall.
‒
Determine the centre of the hob.
‒
Comply with the safety clearances for the hob.
→
We recommend fitting the extractor hood such that
the lower edge of the glass screen is in line with the
lower edges of the adjacent wall-hung cabinets.
5.
Place the template against the line drawn on the
wall and secure it in place.
6.
Mark the positions for the screws.
7.
For the installation with the flue cover, separate the
template along the marked cut line.
8.
Drill the 8 mm diameter holes to a depth of 80 mm
for the fastenings.
9.
Remove the template.
10.
Insert the wall plugs flush with the wall.