background image

1.2 Operating for the first time

Before operating the appliance for the first time,

please pay attention to the following notes:

– The appliance must be installed and connected

by a specialist before it is operated for the first
time.

– Conscientiously read through the operating and

assembly instructions before operating the
appliance for the first time.

– Remove the packaging from the appliance and

dispose of it properly! Pay attention to the fact
that there are accessories in the packaging!
Keep packaging elements (e.g. plastic foil,
styrofoam parts) out of the reach of children!

– Thoroughly clean the appliance before using it

for the first time (see chapter “Cleaning and
care”).

– Before operating the appliance for the first time,

check that the mains connection is in proper
working order.

1.3 About use

The appliance is intended solely for use in the
household and must not be put to any other uses.

– In the event of malfunctions, first of all check the

household fuses. If the problem has nothing to
do with the power supply, please contact your
specialist dealer or your local Gaggenau after-
sales service.

– When children become old enough to operate

the appliance, it is the legal responsibility of the
parents or legal guardians to ensure that they
are instructed in safe practices by qualified
persons.

5

Summary of Contents for AI 540

Page 1: ...Operating and assembly instructions AI 540 AI 541 Freely Suspended Insular Hood...

Page 2: ......

Page 3: ...1 1 For your safety Page 4 1 2 Operating for the first time Page 5 1 3 About use Page 5 2 Features Page 6 3 Operation Page 7 9 4 Cleaning and care Page 10 11 5 Maintenance Page 12 6 Assembly instruct...

Page 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Page 5: ...Always turn hood ON when cooking at high heat or when cooking flaming foods c Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter d Use proper pan size Alway...

Page 6: ...nce Do not clean the appliance with a steam cleaning apparatus or with water pressure because this poses a risk of short circuits Isolate the appliance from the mains during every maintenance operatio...

Page 7: ...ut of the reach of children Thoroughly clean the appliance before using it for the first time see chapter Cleaning and care Before operating the appliance for the first time check that the mains conne...

Page 8: ...of 7 4 7 11 AD 011 026 for ceiling heights of 7 11 9 AD 011 036 for ceiling heights of 9 9 9 Installation accessories for circulating air mode Stainless steel design ventilation duct AD 010 126 for ce...

Page 9: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Page 10: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Page 11: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Page 12: ...out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 130 F 55 C where it should be supported...

Page 13: ...ent solution Do not use any strong caustic or abrasive cleaning agents Do not use any abrasive sponges or brushes either Clean the stainless steel extractor hood with stainless steel cleaner Cleaning...

Page 14: ...the safety of the appliance Unauthorised tampering with the appliance will invalidate any warranty claims Only use original spare parts Lamp replacement Caution disconnect the power supply before repl...

Page 15: ...tion and be connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit f NEVER place a switch where it can be reached from a tub or shower WARNING To reduce the risk of fire use onl...

Page 16: ...that is not in operation During the course of planning a chimney sweep must be consulted if a room air dependent hearth is operated in the same room as the one in which a hood is operated in the exha...

Page 17: ...air line The condensate separator must still be acciessible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air...

Page 18: ...20 Note this hood has been approved for installations as low as 30 and as high as 36 above the cooktop Circulating air mode only there are four brackets which fix the circulating air switch module to...

Page 19: ...screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Fig 22 and 23 Cut the flexible air pipe to the required length and fix it to the...

Page 20: ...hich has no magnetic strips with 2 screws on the top of the support frame Fig 26 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the first...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...780 Dedham Street Canton MA 02021 USA Telephone 877 4GAGGENAU Fax 714 901 5360 www gaggenau usa com Gaggenau Hausger te GmbH Carl Wery Stra e 34 81739 M nchen Germany www gaggenau com 9000220009 EB 8...

Reviews: