12

6.1 T

echnical data

AI 200:

max. weight depending on version 45 kg
dimensions  

998 x 648 mm

AI 201: max. weight depending on version 45 kg

dimensions  

998 x 648 mm

AI 202: max. weight depending on version 43 kg

dimensions  

998 x 648 mm

AI 203: max. weight depending on version 43 kg

dimensions  

998 x 648 mm

Electrical connection

Pay attention to the rating plate data.

The mains connecting cable must at least
correspond to the type H 05 VV-F G 0,75.

The appliance must only be connected by an

authorised specialist.

The specialist is respon

-

sible for perfect functioning of the appliance at its
installation location. He must explain the operating
principle of the appliance to the user with refe-
rence to the operating instructions. He must explain
to the user how the appliance can be isolated from
the mains whenever required.

Connection possibilities

The plug of the connecting cable is inserted into

the socket on the ceiling. If this is not possible, the
disconnection of all the poles of the appliance from
the mains must be possible by way of the domestic
fuse, or by using an accessible disconnecting device
with a contact gap of at least 3.0 mm.

6.2 Installation

The applicable regulations of the energy supply

companies and the 

regional construction

regulations

must be observed when installing 

the hood.

The

minimum distance

from the cooking surface

to the bottom edge of the extractor hood is 600 mm
for electrical appliances. The 

minimum distance

from the bottom edge of the pot stand to the bottom

edge of the extractor hood is 650 mm for gas
appliances.

The hood can be used in the exhaust or 

circulating

air 

mode. The exhaust air can be routed into a

separate exhaust air shaft or directly into the open
through the outside wall.

It is not allowed to pass the exhaust air into a flue 
or exhaust air chimney that is in operation or into a
shaft that is linked to the heating basement. Consult
the chimney sweep responsible for your district
whenever you wish to pass the exhaust air into a
chimney that is not in operation.

During the course of planning

, a chimney sweep

must be consulted if a room air-dependent hearth 
is operated in the same room as the one in which a
hood is operated in the exhaust air mode. Adequate
incoming air must be ensured. The applicable
construction and safety regulations must be
observed.

Adequate incoming air must be ensured if a wood,
coal, gas or oil heater or an open hearth is operated
in the same room as the one in which the hood is
installed.

Safe operation is possible whenever the partial
vacuum in the place where the firing equipment 
is installed does not exceed 4 Pa (0.04 mbar). 
This can be achieved whenever the air needed for
combustion is able to enter through openings that
cannot be sealed, for example in doors, windows,
incoming/exhaust air wall boxes or other technical
means.

6. Assembly instructions

Summary of Contents for AI 200

Page 1: ...Operating and Assembly Instructions AI 200 AI 201 AI 202 AI 203 Extractor Hood...

Page 2: ......

Page 3: ...1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 Maintenance Page 11 6 Assembly instructions...

Page 4: ...otes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the lasting va...

Page 5: ...ing more than 3 gas operated rings at the same time please operate the extractor hood at level 2 or higher This prevents a build up of heat in the appliance For safety reasons do not place any heavy o...

Page 6: ...ime see chapter Cleaning and care Before operating the appliance for the first time check that the mains connection is in proper working order This appliance is labelled in accordance with the Europea...

Page 7: ...2 m AD 011 026 for ceiling heights of 2 42 2 74 m AD 011 036 for ceiling heights of 2 74 3 00 m Installation accessories for circulating air mode Stainless steel design ventilation duct AD 010 126 for...

Page 8: ...ation by pressing the key see Fig 4 When you briefly press the key the lighting is increased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Page 9: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Page 10: ...f time for all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance wh...

Page 11: ...s out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported ver...

Page 12: ...al filter must be replaced approximately once a year If no activated charcoal filter is installed kitchen smells will not be eliminated The activated charcoal filter KF 001 010 is available through yo...

Page 13: ...tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot shortly after use...

Page 14: ...e from the cooking surface to the bottom edge of the extractor hood is 600 mm for electrical appliances The minimum distance from the bottom edge of the pot stand to the bottom edge of the extractor h...

Page 15: ...essible after installation The duct units listed below are available depending on the height of the ceiling Installation accessories for exhaust air mode Stainless steel design ventilation duct AD 010...

Page 16: ...can only be used in exhaust air mode The exhaust air is conveyed upwards through an externally attached fan via a ventilation shaft or directly into the open air through the outer wall The extraction...

Page 17: ...t the minimum distance between the hob and the extractor hood is maintained 600 mm for an electric hob and 650 mm for a gas hob Circulating air mode only there are four brackets which fix the circulat...

Page 18: ...screws to the ceiling Circulating air mode only assemble the circulating air switch module and fix it to support frame Fig 22 and 23 Cut the flexible air pipe to the required length and fix it to the...

Page 19: ...hich has no magnetic strips with 2 screws on the top of the support frame Fig 26 14 The second top chimney duct which has magnetic strips should be slightly bent open in order to slide over the first...