Cleaning the extractor hood

Clean the 

extractor hood

and the 

aluminium-

design ventilation ducts (LK 590-011/021/031)

with a soft cloth and mild detergent solution only.

Clean the 

stainless-steel design ventilation

ducts (LK 590-010/020/030) 

with mild detergent

solution and apply stainless steel care agent to the
metal surface using a soft cloth.

Cleaning the 

glass plates

Apply commercially available window cleaning
agent with a soft, moist cloth. 
To facilitate cleaning, you can detach the glass 
plates as follows:  
Detach the grease filters. In the extractor hood, you
will find two openings on the upper side through
which you can lift the glass plates singly with a
blunt object (e.g. handle of a wooden spoon) to
detach them with greater ease. The remaining
glass plates can then be lifted from above.
If they are extremely soiled, the glass plates can be
cleaned in a dishwasher at a maximum temperature
of 55 °C.

Note: 

when putting the glass plates back in place,

make sure that you do not scratch the chimney. 
Replace the glass plates with the printed side 
facing down. Position the glass plates at the chim-
ney side first.  

Cleaning the 

aluminium panel

Clean the control panel with a sponge and mild de-
tergent solution only. Dry with a soft, dry cloth. Do
not use any strong or caustic cleaning agents or
brushes and abrasive cleaner to clean it. Do not use
strongly alkaline cleaning agents (such as oven
spray) because these are aggressive to the 
aluminium surface. Do not use any abrasive 
sponges either.

10

Fig. 15

Summary of Contents for AH 592-120

Page 1: ...Operating and assembly instructions AH 590 120 AH 592 120 Freely Suspended Insular Hood...

Page 2: ...120 Preface 1 Important notes Page 3 4 1 1 For your safety Page 3 1 2 Operating for the first time Page 4 1 3 About use Page 4 2 Features Page 5 3 Operation Page 6 8 4 Cleaning and care Page 9 10 5 M...

Page 3: ...important notes on use installation and maintenance of the appliance On the following page you will find important notes on safety and operation These will serve to ensure your personal safety and the...

Page 4: ...poses a risk of short circuits Isolate the appliance from the mains during every maintenance operation To do this remove the mains plug or actuate the corresponding fuse If the mains plug is not acce...

Page 5: ...o the fact that there are accessories in the packaging Keep packaging elements out of the reach of children Thoroughly clean the appliance before using it for the first time see chapter entitled Clean...

Page 6: ...eights of 2 64 2 89 m LK 590 030 for ceiling heights of 2 89 3 14 m Aluminium design ventilation duct LK 590 011 for ceiling heights of 2 39 2 64 m LK 590 021 for ceiling heights of 2 64 2 89 m LK 590...

Page 7: ...tion by pressing the key see Fig 4 When you briefly press the key the lighting is in creased up to the maximum level You can dim the lighting to the required level by keeping the key pressed Fan level...

Page 8: ...ess the Int key while the hood is running at fan level 1 2 or 3 the electronic control will switch back automatically to the previously selected fan level after 5 minutes see Fig 7 If you would like t...

Page 9: ...all levels is ten minu tes After these ten minutes the ventilation switches off but the lighting stays on Interval ventilation Interval ventilation is a special feature of this appliance which period...

Page 10: ...out of the holder repeat the operation for the other grease filters You can clean the stainless steel grease filters in a dishwasher at a maximum temperature of 65 C where it should be supported vert...

Page 11: ...ngly with a blunt object e g handle of a wooden spoon to detach them with greater ease The remaining glass plates can then be lifted from above If they are extremely soiled the glass plates can be cle...

Page 12: ...ce Improper tampering will render all warranty claims null and void Lamp replacement Caution disconnect the power supply before replacing lamps switch off the fuse Caution lamps may still be hot short...

Page 13: ...p to the bottom edge of the hood is for electrical appliances 600 mm and for gas appliances 700 mm The extractor hood was conceived for the exhaust air mode The exhaust air can be routed into a se par...

Page 14: ...ndensate or rain water from an uncovered exhaust air shaft our condensate separator RV 060 150 must be installed in the exhaust air line The condensate separator must still be accessible after install...

Page 15: ...15 minutes if the hood is running on a minimum of level 2 Otherwise there is a risk of burns when touching the exterior of the ex tractor hood The following note applies to extractor hood AH 592 120...

Page 16: ...RONT must be on the same side as the control panel Fig 20 Ventilation ducts LK 590 020 030 021 031 only the enclosed extension module should be mounted on top of the support frame Follow the above ins...

Page 17: ...ventilation ducts only LK 590 010 020 030 pull the protective film off the metal surface 8 Place both ventilation ducts over the support frame Take care not to scratch the sensitive duct surface 9 At...

Page 18: ...on the support frame Fig 24 Note avoid scratches when pulling the ele ments apart by placing the assembly template for example over the top edge of the bottom duct to protect it 15 Replace the glass p...

Reviews: