23
Sensor control
In automatic mode, a sensor in the extractor hood
detects the intensity of the cooking and roasting fumes.
Depending on the setting of the sensor, the fan
automatically switches to another fan setting.Depending
on the setting of the sensor, the fan automatically
switches to another fan setting.Depending on the
setting of the sensor, the fan automatically switches to
another fan setting.
Default sensitivity setting: 2
Lowest sensitivity setting: 1
Highest sensitivity setting: 4
If the sensor control responds too quickly or too slowly,
it can be changed accordingly:
1
When the fan is switched off, press the
<
button
and hold it for approx. 4 seconds. The setting is
displayed.
2
Press the 1, 2, 3 or
Ž
button to change the setting
of the sensor control.
3
To confirm the entry, press and hold the
<
button
for approx. 4 seconds.
Saturation display
When the metal grease filters are saturated, a signal
sounds for approx. 4 seconds after the fan is switched
off. The
œ
saturation indicator also lights up.
▯
If you have not yet done so, the metal grease filters
should be cleaned now. For instructions on how to
clean the metal grease filters, please refer to the
section
Cleaning and maintenance
.
▯
While the saturation indicator is lit up, it can be
reset. To do this, press the
œ
button.
Lighting
The lighting can be switched on and off independently
of the ventilation.
Press the
@
button.
Setting the brightness
Press and hold the
@
button until the desired
brightness is reached.
Audible signal
Switching on the acoustic signal
When the fan is switched off, press the
#
and
Ž
at the
same time for approx. 3 seconds. A signal sounds as an
acknowledgement.
Switching off the acoustic signal
Repeat the "Switching on the acoustic signal" process.
Button 1 = Sensitivity 1
Button 2 = Sensitivity 2
Button 3 = Sensitivity 3
Ž
but-
ton
= Sensitivity 4