 Operating the appliance      

en

Intermittent mode

Intermittent mode automatically switches on the 
extractor hood for 10 minutes every hour. The function 
switches itself off again after 24 hours.

This function can be activated from the control panel or 
using the remote control.

Note: 

If intensive mode or the run-on function has been 

activated, the intermittent function will not be available.

Switching on intermittent mode from the control 
panel

1

Press the 

ÿ

 and 

@

 buttons at the same time. 

 will 

appear on the display.

2

Press the 

@

 or 

 A

 button to set a different fan 

setting.

3

Press the 

ÿ

 and 

@

 buttons at the same time to 

confirm the fan setting for intermittent mode.

Switching on intermittent mode using the remote 
control

1

Press the 

g

 button. 

 will appear on the display.

2

Press the 

@

 or 

 A

 button to set a different fan 

setting.

3

Press the 

g

 button to confirm the fan setting for 

intermittent mode

Note: 

Pressing any of the buttons (except the button for 

the light) will deactivate intermittent mode.

Run-on function

The run-on function allows the extractor hood to 
continue running for a few minutes after it has been 
switched off. This eliminates any remaining cooking 
smells. The extractor hood will then switch itself off 
automatically.

Switching on

Note: 

If intensive mode has been activated, the run-on 

function will not be available.

Press the 

ž

 button on the control panel or on the 

remote control.

The fan will run for 10 minutes at setting 

 and a dot will 

flash on the display during this time. Then the fan will 
switch itself off automatically.

Switching off

Press the 

ž

 button on the control panel or the extractor 

hood's remote control.

This will deactivate the run-on function immediately.

Lighting

Press the 

@

 button on the control panel or the 

=

 button on the remote control.

Saturation signal

The following will happen when the filters are saturated:

The 

ª

 symbol appears in the display: Clean the 

metal grease filter

The 

 symbol appears in the display and a signal 

sounds: Replace the activated charcoal filter 

See the "CleanAir air recirculation module" printed 
supplement or the section entitled

~

 "Cleaning and 

maintenance" on page 8

Resetting the saturation signal

When the fan is switched off, the signal is also switched 
off.

The relevant filter(s) should be cleaned now if you have 
not already done so.

Switching over the appliance to air recirculation

1

Switch off the appliance.

2

Press the 

ÿ

 and 

ž

 buttons on the control panel at 

the same time until the 

 indicator lights up. Then 

release the buttons.

The 

 indicator will go out shortly afterwards. The 

electronic controller has now been switched over to air 
recirculation mode.

Switching over the appliance to air extraction

Note: 

The default setting is air extraction mode.

1

Switch off the appliance.

2

Press the 

ÿ

 and 

ž

 buttons on the control panel at 

the same time until the 

ª 

 indicator lights up. Then 

release the buttons. 

The 

ª

 indicator will go out shortly afterwards. The 

electronic controller has now been switched over to air 
extraction mode.

Summary of Contents for AC250190

Page 1: ...en Instruction manual AC250190 Extractor hood...

Page 2: ...installation instructions for future use or for subsequent owners The appliance can only be used safely if it is correctly installed according to the safety instructions The installer is responsible f...

Page 3: ...therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat produci...

Page 4: ...fective appliance may cause electric shock Never switch on a defective appliance Unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service R...

Page 5: ...the air back into the room Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed thro...

Page 6: ...old the button 2 Attach the appliance to the mains voltage A long audible signal sounds The remote control has been connected to the appliance Note If no audible signal sounds within 30 seconds repeat...

Page 7: ...ol The fan will run for 10 minutes at setting and a dot will flash on the display during this time Then the fan will switch itself off automatically Switching off Press the button on the control panel...

Page 8: ...se filters also clean the holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can us...

Page 9: ...event fat from dripping out 4 Clean the appliance from the inside 5 Clean the metal grease filter and let it dry before refitting it Installing the metal mesh grease filter 1 Insert metal grease filte...

Page 10: ...after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer s...

Page 11: ...11 Accessories for air recirculation mode en _Accessories for air recirculation mode Accessoriesforairrecirculationmode not supplied AA010810 AA200110...

Page 12: ...DJJHQDX DXVJHUlWH PE DUO HU 6WUD H 0 QFKHQ 50 1 ZZZ JDJJHQDX FRP 9001161261 9001161261 970412 en...

Reviews: