9
8/18 REV. 2/23
GB808HVB
-
100 INSTALLATION TOOL
Open oil reservoir cap &
fill reservoir
hydraulic
oil reservoir
PULL/RETURN
Booster Assembly
Four
-
Way Valve
Air flow pushes booster assembly
piston back to RETURN position
Incoming Plant Air
90 PSI (6.2 bar) Min.
Pintail Collection bottle
Connect pintail evacuation
tube to tool
Pintails extracted from tool and
collected in collection bottle
Connect hydraulic line to tool
Hydraulic oil flows from booster
assembly thru hydraulic line into
tool
Tool rests on hook when not in use,
shutting off air flow to vacuum
Air flow pushes booster assembly
piston forward to PULL position
Air Filter/Regulator
Air flows from tool and into
four
-
way valve when actuator
depressed. When actuator is
released, four
-
way valve
spring returns
Connect air line to tool
direction of
PULL
pressurization
direction of RETURN
pressurization
Air flows from regulator and
into tool
When actuator in tool is released,
return pressure begins air flow from
four
-
way valve thru valve on front of
powerunit and into vacuum regulator
HOW TO SET
-
UP THE GB808HVB
-
100 POWER UNIT Cont.
WARNING:
Only qualified and trained operators shall install, adjust or use the assembly power tool for non
-
threaded
mechanical fasteners.
WARNING:
Operator
MUST
read and understand all warnings and cautions.
WARNING:
It is required that eye protection, hearing protection and foot protection be worn during operation.
WARNING:
The users or the user
’
s employer must assess specific risks that could be present as a result after each use
based on their application.
●
Ensure there is adequate clearance for tool and operator's hands before proceeding. Keep fingers clear of any
moving parts. Keep fingers clear from fasteners and installed materials. Severe personal injury may result.
●
Verify that hydraulic hose fittings and couplings, air and electrical connections are secure.
●
Verify
the air lines and/or hydraulic hoses are not a trip hazard.
●
Ensure that there are no electrical cables, gas pipes, etc., which can cause a hazard if damaged by the tool.
●
Ensure Do not use as a hammer to force fasteners into holes or otherwise abuse tool.
WARNING:
Do not actuate fastener in the air. Personal injury from fastener ejecting may occur.
WARNING:
Do not use in explosive atmosphere.
WARNING:
Ensure air hose is securely connected to avoid possible hose whipping.
WARNING:
Always disconnect air supply when tool is not in use to prevent accidental start
-
up.
CAUTION:
Do not use beyond the design intent.
Image may not reflect actual tool
Summary of Contents for GB808HVB-100
Page 14: ...14 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL OVERHAUL BOOSTER ASSEMBLY...
Page 17: ...17 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT GB808HVB 100 POWERUNIT...
Page 20: ...20 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL GB808HVB 100 POWERUNIT WIRE DIAGRAM...
Page 23: ...23 8 18 REV 2 23 GB808HVB 100 INSTALLATION TOOL This page intentionally left blank...