12
Rev. 4/22
GB714SH INSTALLATION TOOL S/N: 1003 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
BLEEDING PROCEDURE:
Note:
•
Air Bleeder Assembly (705153) (sold separately) is required.
* FILLING & BLEEDING VIDEO AVAILABLE AT:
http://www.gagebilt.com/rivet_tools_videos.php
Air Bleeder
Assembly
(704153)
Images may not reflect actual tool
IMPORTANT:
Be sure to use thread sealant on all hydraulic fittings, Loctite® 545 or equivalent or a non
-
hardening Teflon® thread
compound such as Slic
-
tite®. Tighten until fitting feels snug and then continue to tighten 1/2 to 1 full turn.
CAUTION:
Over tightening
can easily distort the threads. DO NOT USE TEFLON® TAPE.
CAUTION:
Teflon® tape is an excellent thread sealer, however, if it is not
properly applied, pieces of Teflon® may enter the hydraulic system and cause malfunction or damage.
1.
Stand handle assembly (744129) on floor, stretch hose and head cylinder assembly (713123) upward and lay flat on a table or
bench. When bleeding tool always keep the head cylinder assembly (713123) higher than the handle assembly (744129).
2.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from manifold
-
handle (744303) hole marked #3. Attach air bleeder
assembly (704153) to manifold
-
handle (744303) hole marked #3 in an upright position.
3.
Connect the tool to air supply and cycle tool ten times holding the lever (704345) down for 2
-
3 seconds between cycles to remove
any air from the tool.
4.
Disconnect air supply. Remove air bleeder assembly (704153) from manifold
-
handle (744303) and replace with button head cap
screw (402482) and stat
-
o
-
seal (S572) and torque to 35
-
40 inch lbs. (3.95
-
4.52 Nm). Do not over tighten.
5.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from bleeder hole on head cylinder assembly (713123) and attach
air bleeder assembly (704153) in an upright position.
6.
Connect air supply. Cycle tool ten times removing any air bubbles.
7.
Disconnect air supply. Remove air bleeder assembly (704153) and replace button head cap screw (402482) and stat
-
o
-
seal (S572)
and torque to 35
-
40 inch lbs. (3.95
-
4.52 Nm). Do not over tighten.
8.
Connect air supply. Cycle tool ten times and check stroke of
.590” (15
mm) using instructions a thr c and diagrams below.
We recommend using dial calipers.
a. With the lever (704345) released, check dimension (A).
b. Holding lever (704345), check dimension (B).
c. Subtract dimension (A) from dimension (B). If stroke is not consistent within 1/64" (.396 mm) repeat bleeding procedure until stroke met.
For your consideration, Gage Bilt offers a depth gage (Pt.# A
-
1935) to help simplify and more accurately check your tool stroke.
Please contact Gage Bilt for more information.
9.
Disconnect air supply.
10.
Re
-
attach lever and pin to lever (704345).
Hole marked #3 on
Manifold Handle (744303)
WARNING:
Do not cycle tool without air bleeder assembly (704153), or the screw and stat
-
o
-
seal, installed in tool head. Severe
personal injury could result.
WARNING:
Use CAUTION when removing screws, air bleeder assembly (704153) (sold separately) and fill bottle (745263).
Hydraulic oil may be under pressure.
CAUTION:
Before filling handle assembly (744129), air piston assembly (744121) must be all the way down.
CAUTION:
When forcing piston rod assembly (714136) downward, with head cylinder assembly (713123) removed, hydraulic oil will eject
forcibly from handle assembly (744129).
CAUTION:
When bleeding tool, ensure tubing is free from kinks or other obstructions.