12
3/21 REV 5/22
GB713SR
-
5 INSTALLATION TOOL
IMPORTANT:
Be sure to use thread sealant on all hydraulic fittings, Loctite® 545 or equivalent or a non
-
hardening Teflon® thread
compound such as Slic
-
tite®. Tighten until fitting feels snug and then continue to tighten 1/2 to 1 full turn.
CAUTION:
Over tightening
can easily distort the threads. DO NOT USE TEFLON® TAPE.
CAUTION:
Teflon® tape is an excellent thread sealer, however, if it is not
properly applied, pieces of Teflon® may enter the hydraulic system and cause malfunction or damage.
1.
Ensure pin and lever on lever assembly (724017) has been removed.
Stand handle assembly (744129) on floor, stretch hose and
head cylinder assembly (713127) upward and lay flat on a table or bench. When bleeding tool always keep the head cylinder
assembly (713127) higher than the handle assembly (744129).
2.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from manifold
-
handle (744303) hole marked #3. Attach air bleeder
assembly (704153) to manifold
-
handle (744303) hole marked #3 in an upright position.
3.
Connect the tool to air supply and cycle tool ten times holding the actuator assembly
-
air (704130) down for 2
-
3 seconds between
cycles to remove any air from the tool.
4.
Disconnect air supply. Remove air bleeder assembly (704153) from manifold
-
handle (744303) and replace with button head cap
screw (402482) and stat
-
o
-
seal (S572) and torque to 35
-
40 inch lbs. (3.95
-
4.52 Nm).
5.
Remove button head cap screw (402482) and stat
-
o
-
seal (S572) from hole marked #4 manifold
-
head assembly (744306) and
attach air bleeder assembly (704153) in an upright position.
6.
Connect air supply. Cycle tool ten times removing any air bubbles.
7.
Disconnect air supply. Remove air bleeder assembly (704153) and replace button head cap screw (402482) and stat
-
o
-
seal (S572)
and torque to 35
-
40 inch lbs. (3.95
-
4.52 Nm).
8.
Connect air supply. Cycle tool ten times and check stroke of
.760” (19.3
mm) using instructions a thru c and diagrams below. We
recommend using dial calipers.
a. With the actuator assembly
-
air (704130) released, check dimension (A).
b. Holding actuator assembly
-
air (704130) check dimension (B).
c. Subtract dimension (A) from dimension (B). If stroke is not consistent within 1/64" (.396 mm) repeat bleeding steps until
stroke met.
For your consideration, Gage Bilt offers a depth gage (Pt.# A
-
1935) to help simplify and more accurately check your tool stroke. Please
contact Gage Bilt for more information.
9.
Disconnect air supply.
10.
Re
-
attach lever and pin to lever assembly (724017).
BLEEDING PROCEDURE:
Note:
•
Air Bleeder Assembly (704153) (sold separately) is required.
* FILLING & BLEEDING VIDEO AVAILABLE AT:
http://www.gagebilt.com/rivet_tools_videos.php
WARNING:
Do not cycle tool without air bleeder assembly (704153), or the screw and stat
-
o
-
seal, installed in tool head. Severe
personal injury could result.
WARNING:
Use CAUTION when removing screws, air bleeder assembly (704153) and fill bottle (745263). Hydraulic oil may be
under pressure.
CAUTION:
Before filling handle assembly (744129), air piston assembly (744121) should be all the way down.
CAUTION:
When forcing piston rod assembly (744136) downward, with head cylinder assembly (713127) removed, hydraulic oil will
eject forcibly from handle assembly .
CAUTION:
When bleeding tool, ensure tubing is free from kinks or other obstructions.
Images may not reflect actual tool.
Hole marked #4 on Manifold
Head Assembly (744306)
*located on far side*
Hole marked #3 on
Manifold Handle (744303)
Air Bleeder Assembly (704153)