WEEKLY PROGRAMMES 
 

It is possible to allocate different programs to different days of the week. To do this, the controller has to be upgrade from 24hr mode (factory 
default) to 24hr/7days mode as follows: 
 

Move the selector to 

0

 position, the display will be Off. Press the 

 key and at the same time turn the selector to 

P

 position maintaining the 

 key at least five seconds. The display will show 

P-SE

 which means that weekly mode has been set.

 

 

SETTING THE DAY: Press the 

 key more than two seconds and the display will show the number of the day. Set the correct number, if 

required, by pressing 

+

 or 

 keys. Press the 

 key and the display will show now the time.  Press again the 

 key and new values will be 

stored. 
 
 

To check a programme or to make a new one press

 PRG 

key: The display will show 

dia1

 .  Press again 

PRG 

key and the display will 

show 

00:00 

 intermittently. Follow now the steps from DAILY PROGRAMMES section until the display shows again  

dia1

 .  Repeat this 

process with the 7 days of the week. When the display shows 

dia7

  the weekly program will be stored by pressing 

+

 key.  

 

 If the display shows 

dia1

 

then, pr key more than three seconds will copy the day 1 program to day 2 and so on. 

 

It is possible to allocate any of the three temperature levels to all the intervals of any day maintaining the relevant  

    

   

7

 

key 

until an audible signal is heard. 
 

 

To turn back a controller from 24hr/7days to a single 24hr press 

PRG 

key more than six seconds. This will restore the factory default settings. 

 
KEYBOARD LOCK 

Press the 

7

 key more than six seconds and the keyboard will be locked. The display will show 

 

 and the controller will keep on 

working internally.  To unlock the keyboard press again the 

7

 key more than six seconds . 

 
4.- CLEANING AND MAINTENANCE  
 

Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.  
 
Do not use solvents or abrasive products for cleaning. 
 
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.                 
 
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way. 
 

5.- TROUBLESHOOTING 

 

- The thermal  radiator does not heat. 

Check the heater or the air inlets are not covered.  

Digital models:  the display shows the time press the 

7

 key to switch on the heater. Check that the 

DAY or NIGHT temperatures are right. 

 

- The room does not reach the right 
 temperature.  

Check the selected temperature is in accordance with the desired temperature. Maybe the room needs 
more heating power. 

 

- DAY and NIGHT luminous indicators 
are lit at the same time. 

Digital models: Continuous mode has been selected. Turn the knob to the “P” position to return to the 
Program mode if required. 

 

- The display shows “Err1” or “Err2”  

Digital models: Contact the after sale service. 

 

- Only daily programmes.

 

The controller is in a single 24hr mode (factory default). See WEEKLY PROGRAMMES section to swift 
to 24hr/7days mode. 

- The keyboard is locked.

 

If the display shows 

 

the keyboard is locked. To unlock the keyboard press the 

7

 key 

more than six seconds. 

 
 

Summary of Contents for RF4P

Page 1: ...IGNER RADIATORS RF4P RF4E RF6P RF6E RF8P RF8E RF10P RF10E RF12P RF12E RF14P RF14E INSTALLATION INSTRUCTIONS AND USER GUIDE Please read these instructions before installing or using this appliance for the first time ...

Page 2: ... a double pole isolating switch having a contact separation of at least 3 mm If the flexible power cable for this unit is damaged it may only be replaced by a repair workshop recognised by the manufacturer as special tools are necessary This appliance must be earthed All models are supplied with an electrical interrupt cut out This will switch off the heater if for any reason it overheats Should t...

Page 3: ...e heater maintains the set temperature with the temperature selector dial Moon mode on the heater maintains a temperature 3ºC lower than the one set with the temperature selector dial The studs and screws are in the accessories bag Hung the unit on the hooks of the brackets By turning the screw the metallic square will go downwards retaining the heater Repeat this on the other bracket Use the heat...

Page 4: ...y of the 48 intervals of 30 minutes of the day SWITCHING ON THE HEATER AND SETTING THE TIME Turn the mode selector dial to P position and press the key more than two seconds The display will show the time intermittently Set the minutes by pressing and keys and press the Set the hours the same way Press once more the key to store the time If at any time it is necessary to set the time press the key...

Page 5: ...d both luminous indicators will be off Press the key to go to the next interval The display will show 00 30 intermittently and again press one of the three keys 7 to allocate SUN MOON or OFF frost protection from 00 30h to 01 00h or press key directly if the existing temperature level is ok Repeat these steps allocating the desired temperatures levels over the 24 hours of the day Press the key at ...

Page 6: ... six seconds This will restore the factory default settings KEYBOARD LOCK Press the 7 key more than six seconds and the keyboard will be locked The display will show and the controller will keep on working internally To unlock the keyboard press again the 7 key more than six seconds 4 CLEANING AND MAINTENANCE Clean and dust with a dry soft cloth only when the unit is disconnected and cold Do not u...

Page 7: ...WIRING sensor controller sensor controller MODELS RF E R heating element Ts safety cut out C three way selector MODELS RF P R heating element Ts safety cut out C three way selector ...

Reviews: