Gabarron PH075 Installation Instructions And User Manual Download Page 2

3.-

Using the panel heater.

NON TIMER MODELS

Open the hinged controls cover to access  the controls. After adjustment the control 
cover closes automatically. 

Switch on the heater by setting one of the two switches marked  I-O  to “ I “. The off 
position is marked “ O “. 

You can select half heat or full heat by setting only one of the switches marked  I-O   to 
“ I “ or by setting the two ones (this feature is not available on 750W models). When the 
heater is generating heat the neon indicator on the switch will be illuminated. 

The heater is fitted with an adjustable thermostat, which enables room temperature to 
be controlled by adjusting the setting accordingly. Turn the thermostat control to the 
maximum (fully clockwise) to heat the room rapidly. When the desired temperature has 
been reached, turn the thermostat control slowly to the left (anti-clockwise) until the 
luminous indicator switches off. By leaving in this position, the heater will automatically 
maintain the selected temperature. 

TIMER MODELS

If the slide switch marked   I -O- 

Ÿ

   is set to the position marked    “ I “ the 

heater will be always on, under the control of the thermostat as a non timer 
model.

If the slide switch marked   I -O- 

Ÿ

   is set to the position marked   “O “ the 

heater will be in the off position. 

If the slide switch marked   I -O- 

Ÿ

   is set to the position marked    “ 

Ÿ

 “  the 

heater will operate automatically. Set the timer by rotating the dial clockwise 
until the correct time is indicated opposite the datum mark. Pull the appropri-
ate segments out to set the desired programme. This programme will repeat 
itself every day. The timer may be set to give as many “on” periods of any 
length as may be required. 

The switch marked  I – II  provides a choice of half heat or full heat. (not 
available on 750W models). When the heater is generating heat the neon 
indicator on the switch will be illuminated. 

3.- Cleaning and maintenance.

Clean and dust with a dry, soft cloth only when the unit is disconnected and 
cold. Do not use solvents or abrasive products for cleaning.

4.- Wiring

PH-125T
PH-150T
PH-200T

PH-075T

PH-075

PH-125
PH-150
PH-200

T:  24h Timer 
E1: Element 1 
E2: Element 2 
S: Safety cut out 
C: Switch 
L: Luminous indicator 
Ta: Ambient thermostat 

Brown :  

Live 

Blue :     

Neutral 

Green and Yellow :   Earth 

The symbol on the product or in its 

packaging indicates that this product may not 
be treated as household waste. Instead it shall 
be handed over to the applicable collection 
point for the recycling of electrical and elec-
tronic equipment. By ensuring this product is 
disposed of correctly, you will help prevent po-
tential negative consequences for the environ-
ment and human health, which could otherwise 
be caused by inappropriate waste handling of 
this product. For more detailed information 
about recycling of this product, please contact 
your local city office, your household waste 
disposal service or the shop where you pur-
chased the product. These instructions are only 
valid in the EU member states.