background image

 

SETUP 

 

WARNING! Never connect the apparatus without it being full of water.  

 
It is necessary to completely ‘drain’ the water heater, the tubes and the taps of air that 
could be inside to avoid disagreeable noises. Before connecting the water heater to the 
network, fill it completely with water by leaving the hot water tap on. Do not turn the 
tap off until the water exits evenly and without noise through the tubes and turn other 
taps on successively. 

MAINTENANCE 

 

IMPORTANT: On a regular basis (once a month) the safety valve must be placed 
in the emptying position in order to check it is not obstructed. If it were, it must be 
replaced by a new one.  

 
In areas where the water has high lime content, we recommend an annual cleaning of 
scale: 1 – Turn off the electric current. 2 – Empty the water heater of water using the 
safety valve. 3 – Disassemble the heating element and the thermostat by removing the 
attachment screws. 4 – Remove the scale deposited as balls or sheets at the bottom of 
the tank and carefully clean the components in contact with the water. Do not remove 
the scale attached to the wall of the tank, since this constitutes an effective protection 
against corrosion. 5 – After cleaning, assemble the components once again and replace 
the connection flange. 6 – Set the water heater up again as described in the “setup” 
section. 
 
If you notice the continual escape of vapour or boiling water through the drainage outlet 
or when you turn on a tap, turn of the electrical input and notify the Technical Help 
Service.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

As part of the policy of continuous product improvement, ELNUR S.A. reserves the right to alter specifications without notice

   

Reviews: