background image

4.-OPERATION 

 

Filling up. Open the shut-off valve once the immersion heater has been installed.Open the hot water 

taps.Water appears as  soon as the unit fills up completely.Close the taps and check the system for 

leaks. 

Do not connect the immersion heater to the mains until you are sure it is full. 

 

Electric connection. Plug it into the mains and press the main power switch to turn the appliance on.A 

light flashes when the heating element is working. 

The thermostat re-activates the heating element after a certain amount of hot water has been used. 

 

Setting  water  temperatures.  The  dial  on  the  thermostat  can  be  used  to  adjust  the  hot  water 

temperature between approximately 30 ºC (minimum position) and 75 ºC (maximum position). 

 

E  Position.  (Energy  saving).The  water  reaches  a  temperature  of  around  55  ºC.Heat  losses  are 

minimum in this position and the formation of lime deposits are practically reduced. 

It is recommended to have the water heater always plugged into the mains, as the thermostat will only 

run  the  unit  when  necessary  to  keep  the  water  at  the  selected  temperature.    The  polyurethane 

insulation foam means that any heat loss will be insignificant. 

 

Draining the unit. The heater should be drained if it is not to be used for extended periods of time and 

if  there  is any  risk  of  freezing  pipes at  the  premises where  it  is installed.The  heater  can be  drained 

using the safety valve.Always remember to: 

- Unplug the unit. 

- Close the water inflow valve. 

- Open the hot water tap. 

 

Unplug the water heater and contact the Technical Assistance Service is you see any continuous steam 

or boiling water coming out of the drain or when you open a tap. 
 

5.- MAINTENANCE 

 

IMPORTANT:  Once  a  month  check  that  the  safety  unit  is  not  blocked.Do  this  by  turning  it  to  the 

drainage position.If it is blocked, it must be replaced by a new one. 

 

Every  two  years  a  technician  needs  to  remove  any  scaling  on  the  element.  The  warranty  does  not 

cover any damages caused if this service is not carried out. 

 

Any overheating by a possible thermostat failure is protected by the safety cut-out device, which stops 

both phases and the immersion heater has no power supply.If this happens, contact our After-Sales 

Service for the unit to be repaired. 

 

Unplug the unit and leave it to cool and then clean it by wiping the unit with a soft cloth or damp 

sponge. 

 

Do not use solvents or abrasive products. Never submerge the immersion heater in water. 

This  water  heater  has  been  manufactured  as  part  of  a  quality  assurance  system  and  using 

environmentally-friendly processes. 

 

 

Summary of Contents for GTB-100

Page 1: ...cciones Las instrucciones deben conservarse para futuras referencias Este manual debe ser conservado y dado a cualquier nuevo usuario Please read these instructions before installing or using this app...

Page 2: ...importante mantener una distancia de 80 cm entre el termo y cortinas u otros objetos inflamables Nunca desmonte los componentes del termo ni los reemplace por otros que no cumplan los requisitos de s...

Page 3: ...00 100 100 100 100 100 B 90 90 100 100 100 100 D 610 910 790 935 1305 1500 E 270 270 350 350 350 350 F 0 0 345 495 845 800 G 430 730 240 240 240 270 H 334 334 500 500 500 500 I 354 354 507 507 507 507...

Page 4: ...m s pr ximo posible al punto de utilizaci n del agua caliente con ello se evitan p rdidas de temperatura del agua en el recorrido por las tuber as Cuando se instale el termo en posici n vertical deja...

Page 5: ...uridad debe ser conectada OBLIGATORIAMENTE a una tuber a de desag e que tenga un di metro por lo menos igual al de la tuber a de conexi n del termo con una inclinaci n continuada y abierta a la atm sf...

Page 6: ...rendido entre los mismos planos horizontales se alados para el volumen de prohibici n y otros verticales situados a 1 20 metros de los del citado volumen En el volumen de PROHIBICI N no se instalar n...

Page 7: ...est instalado es recomendable vaciar el termo El vaciado se puede hacer por el drenaje de la v lvula de seguridad En todo caso Cortar la corriente Cerrar el grifo entrada agua en la instalaci n Abrir...

Page 8: ...orna de conexi n 2 Termostato y limitador t rmico 3 Resistencia 1 x 2000W 4 Piloto de funcionamiento MODELOS GTB 80 GTB 100 GTB 150 y GTB 200 1 Termostato 2 Limitador t rmico 3 Resistencias 2 x 1000W...

Page 9: ...ws bedding papers clothes etc and curtains at least 80cm from the front sides and rear of the water heater Never dismantle the immersion heater components or replace them with others that do not meet...

Page 10: ...0 B 90 90 100 100 100 100 D 610 910 790 935 1305 1500 E 270 270 350 350 350 350 F 0 0 345 495 845 800 G 430 730 240 240 240 270 H 334 334 500 500 500 500 I 354 354 507 507 507 507 K 615 915 803 948 13...

Page 11: ...d to place it as close as possible to the point where the hot water will be used this will avoid temperature losses of the water as it goes through the pipes When the immersion heater is installed ver...

Page 12: ...f the safety unit MUST be connected to a drain pipe which is at least equal in diameter to that of the immersion heater connection pipe with a continuous slope and open to the atmosphere ensuring ther...

Page 13: ...bedded in the floor PROTECTION VOLUME It is the volume situated within the horizontal planes stated for the prohibited volume plus other vertical ones 1 20 metres away from those of that volume No swi...

Page 14: ...he unit The heater should be drained if it is not to be used for extended periods of time and if there is any risk of freezing pipes at the premises where it is installed The heater can be drained usi...

Page 15: ...50 1 Connection block 2 Thermostat and thermal cut out 3 Heating element 1 x 2000W 4 Pilot lamp MODELS GTB 80 GTB 100 GTB 150 and GTB 200 1 Thermostat 2 Thermal cut out 3 Heating elements 2 x 1000W 4...

Page 16: ...19 57 14 www elnur es Como parte de la pol tica de mejora continua Elnur s a se reserva el derecho a realizar modificaciones t cnicas sin previo aviso As a part of the policy of continuous product imp...

Reviews: