18
KEY “
-
“
Press the key to
decrease different
values
3. OPERATING INSTRUCTIONS
CAUTION: DO NOT USE THIS HEATER TO DRY CLOTHES. Do not cover this heater at any time.
CONNECTION/ DISCONNECTION
Power switch. All models are equipped with a switch on the back side panel. It is
used to connect and disconnect ECOMBI.
KEYBOARD:
KEYBOARD LOCK:
In any operation mode it is possible to lock the keyboard holding the keys and simultaneously for several seconds.
When the keyboard is locked, if any button is pressed, display will show and the appliance will not respond
.
To unlock the keyboard hold the keys simultaneously again for several seconds.
SYSTEM TIME SETTING
It is necessary to set the system time for the appliance to follow correct programming and to adjust it correctly to the off peak
time periods. Off peak periods have to fit with the ones established in GENERAL SETTINGS part as P1, P2, P3, and P4 (please
go to “General Settings”).
To set the system time, hold the key for 8 seconds. The Hour values are changed with the and keys.
Then press the key to save and proceed to change the minutes values. Press again to save and proceed to change
the week day if weekly programming option is enabled in the GENERAL SETTINGS part:
If it is necessary to set up different values for different days in a week, please go to “General Settings” in this manual and change
P7 setting to “ON” position. Once it is changed come back to “System time setting”, set hour, minutes, week’s day and validate.
i
ECOMBI does not change automatically from summer time to winter time or vice versa. Depending on
the tariff it may be necessary to change the clock settings to fit these two timings.
К
EY “
+
”:
Press the key to increase
different values
“Operation mode” key:
Press the key to select different
operation modes.
FROST PROTECTION
AUTOMATIC STORAGE HEATER
EMITTER
ECOMBI MANUAL
ECOMBI AUTOMATIC
“Clock” key:
Press the key to display date and
time. Hold it for more than 8
seconds to change values.