28
Gabarrón CM & CMX
9 TECHNICAL DATA
CMX15
CMX18
CM15
CM18
Frequency
Hz
50
50
50
50
Connection N~
Output limited to
18kW
; Maximum intensity
A
-
26.0
-
26.0
Output limited to
15kW
; Maximum intensity
A
21.7
26.0
21.7
26.0
Output limited to
13kW
; Maximum intensity
A
21.7
-
21.7
-
Output limited to
12kW
; Maximum intensity
A
21.7
26.0
21.7
26.0
Output limited to
11kW
; Maximum intensity
A
21.7
-
21.7
-
Output limited to
10kW
; Maximum intensity
A
21.7
-
21.7
-
Output limited to
9kW
; Maximum intensity
A
13.0
13.0
13.0
13.0
Output limited to
8kW
; Maximum intensity
A
13.0
-
13.0
-
Output limited to
7kW
; Maximum intensity
A
13.0
-
13.0
-
Output limited to
6kW
; Maximum intensity
A
8.7
13.0
8.7
13.0
Output limited to
5kW
; Maximum intensity
A
13.0
-
13.0
-
Output limited to
4kW
; Maximum intensity
A
8.7
-
8.7
-
Output limited to
3kW
; Maximum intensity
A
13.0
13.0
13.0
13.0
Connection 230V~ single phase
1
1
1
1
Nominal maximum intensity
18kW
A
-
78.3
-
78.3
Nominal maximum intensity
15kW
A
65.2
65.2
65.2
65.2
Maximum converted intensity at
13kW
A
56.5
-
56.5
-
Maximum converted intensity at
12kW
A
52.2
52.2
52.2
52.2
Maximum converted intensity at
11kW
A
47.8
-
47.8
-
Maximum converted intensity at
10kW
A
43.5
-
43.5
-
Maximum converted intensity at
9kW
A
39.1
39.1
39.1
39.1
Maximum converted intensity at
8kW
A
34.8
-
34.8
-
Maximum converted intensity at
7kW
A
30.4
-
30.4
-
Maximum converted intensity at
6kW
A
26.1
26.1
26.1
26.1
Maximum converted intensity at
5kW
A
21.7
-
21.7
-
Maximum converted intensity at
4kW
A
17.4
-
17.4
-
Maximum converted intensity at
3kW
A
13.0
13.0
13.0
13.0
S.H.W. available time with
15kW
min
5’49”
5’49”
-
-
S.H.W. available time with
13kW
min
6’42”
-
-
-
S.H.W. available time with
12kW
min
7’16”
7’16”
-
-
S.H.W. available time with
11kW
min
7’56”
-
-
-
S.H.W. available time with
10kW
min
8’43”
-
-
-
S.H.W. available time with
9kW
min
9’41”
9’41”
-
-
S.H.W. available time with
8kW
min
10’54”
-
-
-
S.H.W. available time with
7kW
min
12’27”
-
-
-
S.H.W. available time with
6kW
min
14’32”
14’32”
-
-
S.H.W. available time with
5kW
min
17’26”
-
-
-
S.H.W. available time with
4kW
min
21’48”
-
-
-
S.H.W. available time with
3kW
min
29’04”
29’04”
-
-
S.H.W. available time with
2kW
min
43’36”
-
-
-
Weight
kg
70
70
32
32
Insulated steel heater header
50 litre stainless steel insulated S.H.W. accumulator
No CFC
-
-
Stainless steel plated resistance elements INCOLOY800
S.H.W.
-
-
Stainless steel plated resistance elements INCOLOY800
Heating
6 litre expansion vessel
S.H.W. 2 litre expansion vessel
-
-
Electronic regulation of heater modulation
Electronic regulation S.H.W..
-
-
Digital display
0-4 kg/cm
2
pressure gauge
Accelerator pump
Automatic purge
TRIACS silent power switches
Heating flow detector
100°C heating temperature limiter
80°C S.H.W. temperature limiter
-
-
3kg/cm
2
heating safety valve
7kg/cm
2
S.H.W. safety valve
-
-
S.H.W. retention valve
-
-
Heating circuit entry valve and filling valve
-
-
Ambient thermostat intake
Anti-electrolysis S.H.W. hoses.
-
-
included
1
using connecting bridge included
Summary of Contents for CM15
Page 15: ...15 12 ESQUEMAS ...
Page 16: ...16 Gabarrón CM CMX ...
Page 30: ...30 Gabarrón CM CMX 12 WIRING ...
Page 31: ...31 ...