background image

Using the Reader

6

Reader Configuration

5

Present the card face-on to the reader until you hear a "bleep". Cards can be presented in rapid succession;
there is no

 

need, for example, to wait for "UNLOCKED" to disappear before presenting another.

If the reader has been enabled for user-code mode at the controller, you can gain access by pressing the # 
key, entering your card number, then pressing the * key.

 

 

   

 

 

 

 

 

 

 

 

   

 

 

9600-0340. 

Installation and User Instructions for S843 Readers, 

Issue 2.2.1 24th November 2009.   G4S Technology Limited 2009. 

FCC Notice: 

This device complies with Part 15 of the FCC Rules. 

Operation is subject to the following two conditions: (1) This device 
may not cause harmful interference, and (2) this device must accept 
any interference received, including interference that may cause 
undesired operation.

Any unauthorized modification to this device may void the authority of 
the user to operate it. This device complies with the provisions of 
European Directive 1999/5/EC. All trademarks acknowledged. Philips 
and MIFARE are registered trademarks of Philips Electronics N.V.

©

About the Reader Messages

}

READY 

 

UNLOCKED 

 

The lock is released and you may open the door.

ACCESS DENIED & LOCKED 

 

You do not have access rights to gain entry, or the reader 

did not read your card properly (in this case, present it again).

ENTER PIN 

 

Enter your PIN. If you make a mistake, the message INCORRECT PIN is 

momentarily displayed, followed by ENTER PIN, to prompt you to try again.

CARD PIN AND #

 – Enter the DESfire card PIN, then press # if the PIN is less than 8 digits.

The reader is waiting for a valid card to be presented.

(Flashing or steady) 

 

These auxiliary indicators can be configured to operate in 

conjunction with conditional commands.

Specifications

Input voltage: 10.2-14Vdc. 
Input current (excl. heater): 190mA @ nom. 12Vdc.
Operating temperature: -4 to 158 F (-20 to 70 C) 
without heater. 
Operating humidity: 15 to 90%, non-condensing.
Maximum read range: 1" (25mm).
Approvals: EN50133, 1999/5/EC, IP65.

°

°

0V

Connect shield at controller
end only (attach to case).

 

   

 

RX+

RX-

TX+

TX-

12V

Reader

Twisted pairs (use
Belden 9503 cable)

 

 

 

Controller
connections 
(20mA current 
loop)

 

The I/O terminal is for 
connection to a RIM (see 
the RIM Instructions).

On completion, re-secure 
the reader to the backplate.

0V

TX+

Do not use

TX-

I/0

RX+

RX-

+V

The reader supports the first two different card types/formats presented after power-up. For example, 
encoded MIFARE and encoded MIFARE DESfire (in this example, unencoded cards would not be 
recognized). The reader enters this configuration mode whenever power is re-applied. 

A reader Setup menu can be displayed by pressing the * and # keys simultaneously while power is 
applied. You can use the menu to change the contrast and language used for the LCD (default English), 
and view the two card types/formats previously programmed. At the prompts, press * for No and # for Yes. 