27
FB-DIS can only be operated when the battery is connected to the input interface under DC
mode, otherwise will report error. The FB-DIS mode is to transfer the capacity of the battery
to be discharged to the input battery through the charger to achieve the purpose of
discharge. For your safety, the discharge current value displayed on the screen should not
exceed the maximum discharge current specified by the battery manufacturer, and the
rated voltage should not be lower than the voltage level recommended by the battery
manufacturer to avoid deep discharge. Select discharge battery type and voltage correctly.
Pb DISCHG
2.0A 10.0V(5P)
SET INPUT BATT
Pb 14.7V(6P)
Set the discharge current value on the second line left side,
set the battery pack voltage on the right side. After set
finished, press and hold Start/Enter for 3 seconds to start the
program.(current
:
0.1
~
12.0A,battery voltage
:
1-10P)
Press ENTER to start program
Set input battery type and voltage, press and hold Start/Enter
for 3 seconds to start the program.
9.3 Pb battery FB-DIS
Pb DICHG
3.4A 12.0V(6P)
4P 0.1A 7.76V
DSC 000:02 00000
Pb AGM CHG
A 4.0V(2P)
Pb 0.4A 7.85V
CHG 000:04 00000
Set discharge current on the left side and nominal voltage on
the right. Press Start /Enter for 3 seconds to start the
discharging process.
(
current
:
0.1
~
3.0A, battery voltage
:
1-10P
)
9.2 Discharging Pb battery
This charge program is specially designed for AGM battery.
The second line left side to set the charge current, the right
side is to set the battery pack voltage. After finished set, press
and hold Start/Enter for 3 seconds to start the program.
(
current
:
0.1
~
12.0A,battery voltage
:
1-10P
)
9.4 AGM battery charge program