INSTALLATION
OPERATION &
MAINTENANCE MANUAL
7.5
-
When reassemble the end caps pay attention not to overturn them. Looking at the O-Ring, be
sure to place end caps with A on the top and B on the bottom.
8.0
SOLENOID VALVES SPACIFICATIONS
G.T. Attuatori solenoid valves are designed for long life, with only one part moving for commutation and
sealing of air compressed flow.
A
B
2 3
1 4
6 5
FIGURE 7
The figure shows the front view of
a piston with the cartridge spring
seats numbered, and the rack
position.
Total number of
cartridge springs
Cartridge springs
All
locations.
positions.
1
2
3
4
5
6
1
1 - 4
2 - 4 - 6 2-3-5-6 1-2-3-5-6
TABLE 3
Cartridge springs orientation chart.
FIGURE 8
The figure shows the internal view of
an end cap, as it must be assembled
on actuator body, with part A on the
top and the part B on the bottom.
Look at the O-Ring
Caution: with upturned end caps,
the actuator cannot operate.