The Sensors

The GSM Alarm Pro 20 has the ability to pair up to 20 sensors. These sensors can be

programmed with their own unique location code so the end user will know exactly which

sensor has been triggered.

The sensors and key fobs are easily paired by using the colour touch screen display on the

board.

Pairing the Sensors

1.  Touch the screen

2.  Press the 

RED

 “SENSOR OPTION”

3.  Choose a location 1-20 to store the sensor using the + and - icons.

4.  Touch the “SELECT LOCATION” - a prompt will appear saying “ACTIVATE SENSOR

NOW”

5.  Activate your sensor

6.  Touch “SAVE-YES” - You will hear 3 beeps to confirm

IMPORTANT - PLEASE READ

Once a sensor has been stored to a location, it cannot be stored to another location without

it being unpaired using a reset.

Pairing the Key Fobs

● Press the 

GREEN

 key option

● It will show 3 positions and have an X or - symbol - this shows whether a keyfob is

  paired to it

● Choose a location from 1-3

● You will then get a prompt to “PRESS KEY FOB A”

● Press the “A” ONLY on your key fob

● This will be followed by a beep to signal it has been paired and stored to that location

Delete Sensors / key fob

To delete the sensors or key fobs, touch the 

YELLOW 

RESET command. It will ask you

whether you want to remove ALL sensors or ALL key fobs.

SIM Active Function

Our GSM Auto Dialler comes with a SIM Active function meaning that it will send a
message every six weeks to a preprogrammed number we at GSM Activate own to prevent
the SIM card being shut down due to inactivity.

www.gsm-activate.co.uk

 - 01273462380 - [email protected]

Summary of Contents for ALARM PRO 20

Page 1: ...Page 1 MODEL ALARM PRO 20 2G GSM ALARM PRO 20 ZONES ...

Page 2: ...olts DC 2 Amp Min Current Used in Standby Mode 50mA Max IP65 Rated Enclosure for Outside Installation Micro 2G or 3G Simcard No Land Line Required Dimensions L100 x W68 x H50mm Dimensions PCB Only L95 x W67mm Sim Active Function Operating Temperature 10 40 C Programmed by Text Message Text to Text Signal Strength Wireless Range Beam 50m Key Fob 50m PIR 80m Battery Backup Disable Zone Remotely Beam...

Page 3: ...ween 0 up to 30 We strongly recommend that you place the unit where it can receive a signal of at lease 10 Less than this will make the unit unreliable Battery Backup In the event of a power failure the internal rechargable battery will be capable of running the unit for 24 hours It will inform you of a MAINS FAILURE by text message as well as when the power is restored with the text message POWER...

Page 4: ...age send the text command as follows IR01 YOUR MESSAGE Default message is IR01 IR02 YOUR MESSAGE Default message is IR02 The detector will reply with the text message MESSAGE STORED By changing position 01 to 20 you can name all 20 individually paired sensors IMPORTANT PLEASE READ Your can only use a maximum of 30 characters including spaces for your customised message How to Setup Call Alerts The...

Page 5: ... cannot be stored to another location without it being unpaired using a reset Pairing the Key Fobs Press the GREEN key option It will show 3 positions and have an X or symbol this shows whether a keyfob is paired to it Choose a location from 1 3 You will then get a prompt to PRESS KEY FOB A Press the A ONLY on your key fob This will be followed by a beep to signal it has been paired and stored to ...

Page 6: ... Once the Alarm has been alarmed it will stay alarmed even after an alarm activation To turn the alarm off and stop further alarm messages you will have to disarm the alarm by text or key fob How to Use The Siren Output The unit has been programmed to trigger the siren for 60 seconds in the event of an alarm activation Once the text message has been received you can STOP the siren sounding by pres...

Page 7: ...etc Once the alarm has been activated it will automatically re arm once the beam has been cleared Disabling Sensor 1 Only If you want to remove sensor 1 from operation you send the text command BEAM1 ON This will re enable sensor 1 BEAM1 OFF This will disable sensor 1 The purpose of this function is to deactivate one sensor whilst retaining the rest of the alarm system This could be for a constant...

Page 8: ... the FAQ s on our website www gsm activate co uk Alternatively email our technical support team at technical gsm activate co uk and we will do our best to respond to your querry within 24 hours Monday Friday Quick Reference 20 07 21 GD Page 8 ...

Reviews: