Product Information

A Multi Purpose GSM Auto Dialler with 2G and 3G capabilities. It is compatible with all
alarm panels with negative triggering through two inputs as well as having relay outputs for
switching on external devices, temperature monitoring, mains failure monitoring with battery
backup and alarm input for PIR’s and IR beams. It also features an on board tilt sensing and
a microphone for covert listening.

Specification

GSM Frequency: Quad band freq 850/900/1800/1900/2100 MHz.
Power Supply Voltage: 9 to 24  volts DC.
Current used in standby mode: 70 Milliamps.
Max current: Up to 2 amps.
Standard 2G or 3G simcard.
No land line required.
Dimensions - L170 x W120 x H60mm
Weight - 360 grams.
Operating temperature: -10...+40°C
Signal strength function.
Stay Active simcard Function.
Watchdog and self repair function.
2 Inputs.
2 - 10 Amp Relay Outputs.
1 Standalone Alarm Sensor Input.
Temperature reading by text messaging.
Temperature Alarm Controller.
45 Degrees Tilt Sensing Alarm.
Mains Failure and Restore Alarm
Battery Backup for up to 24 hours standby.
Microphone you can call into and listen to the surroundings of unit.

Page 3

Summary of Contents for 3GADV2

Page 1: ...GSM 3G AUTO DIALLER PLUS Control and Monitoring from your mobile phone www gsm activate co uk Page 1 MODEL NUMBER 3GADV2 ...

Page 2: ...ore Input Text Messages How to Set Phone Call Alerts and Text Messages 8 Activating the Output Relays 9 Activating Input 1 and Input 2 Activating the Alarm PIR IR Beam 10 Mains Failure Monitoring Battery Back Up Tilt Alarm Function Microphone 11 Temperature Monitoring 12 Quick Programming Guide Factory Reset 13 Installation Diagrams 14 Important Installer Notes Page 2 ...

Page 3: ...eq 850 900 1800 1900 2100 MHz Power Supply Voltage 9 to 24 volts DC Current used in standby mode 70 Milliamps Max current Up to 2 amps Standard 2G or 3G simcard No land line required Dimensions L170 x W120 x H60mm Weight 360 grams Operating temperature 10 40 C Signal strength function Stay Active simcard Function Watchdog and self repair function 2 Inputs 2 10 Amp Relay Outputs 1 Standalone Alarm ...

Page 4: ...ond to indicate when a signal has been found Ready LED green The green LED will come on when the unit is ready for operation Charger LED red When the red light is on it indicates that the battery is in charging mode Battery Link remove to disconnect battery from use Dipswitch 1 If Dipswitch 1 is set to the OFF position it will ONLY search for a 2G signal on startup 2 If Dipswitch 1 is set to the O...

Page 5: ...ILE NETWORK 1 Slide back the sim door and lift it up 2 Slide the simcard in to the door making sure that the clipped corner of the simcard lines up with the clipped corner of the sim holder 3 Close the sim door 4 Slide the sim door to lock the simcard in place Connect 9 through to 24 volts DC to the input connector as per figure 1 Once power has been applied referring to figure 1 the blue network ...

Page 6: ... Send a text message to the sim card A maximum if 15 digits per phone number SAVE1 07712345678 This stores the mobile landline phone number as contact number 1 SAVE2 01903123456 This stores the mobile landline phone number as contact number 2 SAVE3 07123456789 This stores the mobile landline phone number as contact number 3 A maximum of 3 phone numbers in total To delete a stored number use DEL fo...

Page 7: ...cluding spaces for your customised message Telephone call alerts The auto dialler can be programmed to send you a telephone call after each text alarm has been sent You will receive approximately three ring tones the unit will then hang up automatically This is to prevent call charges being incurred To set call alerts to ON please send the text message CALL ON The unit will reply back call on To d...

Page 8: ...1 REL1 OFF This will turn off relay 1 REL2 ON This will turn on relay 2 REL2 OFF This will turn off relay 2 After each operation the unit will reply with a status report REL1 ON OFF It is possible to pulse relay 1 2 for a period of 17 seconds You will need to send a text as follows PUL REL1 This will Pulse relay 1 for 17 seconds PUL REL2 This will Pulse relay 1 for 17 seconds The unit will reply b...

Page 9: ...nected using the links provided in the clear bag By not connecting the battery switch the battery back up will not work Please refer to PCB reference on page 4 Tilt Alert Alarm The unit has a tilt sensor onboard to monitor movements for applications such as landslides theft etc To activate the tilt alarm please send the text message TILT ON This will turn ON the tilt sensor monitoring When the til...

Page 10: ...t by sending the text command READ You will receive a text acknowledgement with the current temperature Example hash plus or minus symbol temperature settemp hash To activate the temperature alarm please send the text message command following the example below 32SETTEMP This will set the alarm for plus 32 degrees centigrade 20SETTEMP This will set the alarm for minus 20 degrees centigrade NOTE If...

Page 11: ...Quick Programming Page 11 ...

Page 12: ...s are cleared reset The Auto Dialer will then be ready for the next trigger input Inputs 1 2 Alarm Input Manual Reset Alarm Input This is triggered by a negative pulse eg pulled to the ground for a period of not less than one second Before this can be triggered you must activate the alarm input by sending the text command as follows The units will need manually activating again once triggered via ...

Page 13: ...e shown on page 5 Before commissioning please ensure the signal strength is suffic ient by sending the SMS text message SIGNAL We strongly recommend you need a score of at least 10 and to try b oth 2G and 3G via dipswitch 1 If you do not receive a good signal please reposition the aerial antenna to im prove the signal strength or alternatively change the netw ork provider as signa l strength can v...

Page 14: ...For more technical support please browse the FAQ s on our website www gsm activate co uk or alternatively email our technical support team at technical gsm activate co uk and we will reply or call back within 24 hours Monday Friday ...

Reviews: