How to use the 2G/3G Door Contact Alarm

Once you have positioned the door contact, the system is now ready to use.

The GSM Door Contact Alarm has two modes, Alarm Mode and Auto Mode.

In alarm mode, you have to arm your alarm manually when required.

In auto mode, the alarm is always armed.

You should choose the mode most suitable to your application.

Your can select the mode you require by sending the text message to the unit as follows:

#

Mode

=

1

Alarm Mode (default)

#

Mode

=

2

#

 

Auto Mode

Mode 1 - Alarm Mode: 

#

mode

=

1

#

Alarm mode is the default mode. You will need to set the alarm to ON before it detects
movement and sends an alarm message.

To set the alarm to ON you will need to send the text message

#

ALARM

=

ON

This will activate the alarm.

#

ALARM

=

OFF

This will deactivate the alarm

It is important to remember that when the alarm has been triggered you will need to reset
the alarm by sending the text message 

#

ALARM

=

ON

#

 each time.

How to use the relay output

Mode 2 - Auto Mode: 

#

mode

=

2

#

The alarm is always armed and will trigger when movement is detected. The alarm will
automatically reset back into armed mode after 20 seconds when no movement is
detected.

(Dipswitch 2= OFF)

ref page 3

The 3G Auto Dialler has a 2 amp relay output which can be used to switch on external
electric devices such as lighting, sirens etc

By texting the unit you can turn the relay ON or OFF, Below are examples on how to do
this.

#

REL

=

ON

This will turn the relay output ON

#

REL

=

OFF

#

 

This will turn the relay output OFF

After each operation the unit will reply with a status report REL ON/OFF

(Dipswitch 2 = ON)

ref page 3

The relay can also be setup to pulse for 20 seconds when the inputs have been triggered.
To activate this mode you need to set DIPSWITCH 2 ON - ref page 3

This can be used to trigger a siren or reset other equipment.

Page 6

Summary of Contents for 3G RF DOOR

Page 1: ...PAGE 1 MODEL RF PIR 2G 3G GSM Door Contact Alarm www gsm activate co uk ...

Page 2: ...w freezing temperatures PIR Specification GSM Module Specification Alert Distance 25 35mm seperation Detection Dual function magnetic door and emergency switch Battery Life 6 Months Dimensions L60xW32xH13mm Wireless Range 20 Meters Product Information GSM Frequesncy Quadband freq 850 900 1800 1900 3G Model 2100Mhz Power Supply Voltage 9 24 volts DC 1 Amp Min Current used in standby mode 60mA Max I...

Page 3: ...R FACING UPWARDS PLEASE SEE PICTURE ABOVE Signal Strength To help make sure that you place the unit in a suitable position you can text the unit to see how much signal strength the detector is receiving by texting the command SIGNAL The detector will perform a test on the signal strength You will receive a text confirming the signal strength between 0 up to 30 We strongly recommend that you place ...

Page 4: ...t is ready for use Please Note To avoid confusion we have colour coded the hash and the equals symbols Example hash 1 2 or 3 equals phone number hash To programme mobile numbers into the unit you will need to send a text with the contact numbers maximum 3 numbers Example 1 07123456789 Then send this as a text to the simcard in the unit with your preferred mobile number 2 07123456789 Then send this...

Page 5: ...sed message Telephone Call Alerts The Door Contact Alarm can be programmed to send you a telephone call after each text alarm has been sent You will receive approximately three ring tones The unit will then hang up automatically This is to prevent call charges being incurred To text call alerts to ON please send the text message CALL ON The unit will reply back with the message CALL ON To disarm c...

Page 6: ...hat when the alarm has been triggered you will need to reset the alarm by sending the text message ALARM ON each time How to use the relay output Mode 2 Auto Mode mode 2 The alarm is always armed and will trigger when movement is detected The alarm will automatically reset back into armed mode after 20 seconds when no movement is detected Dipswitch 2 OFF ref page 3 The 3G Auto Dialler has a 2 amp ...

Page 7: ... that the devices are matched to the receiver on the dialler 1 Hold down the pairing button on the RF Module for 3 seconds refer to figure 1 2 Trigger the door switch 3 The RF module has a RED LED which will flash when pairing in complete Figure 1 Pairing the Wireless Door Sensors ...

Page 8: ...n necessary The GREEN ready LED will flash eight times Dipswitch Settings Dipswitch 1 ON 3G Selected OFF 2G Selected Dipswitch 2 ON Pulse Relay 20 seconds OFF Pulse Relay Off For more technical support please browse the FAQ s on our website www gsm activate co uk Alternatively email our technical support team at technical gsm activate co uk and we will do our best to respond to your querry within ...

Reviews: