![G-Power America GN5250DCS Owner'S Manual Download Page 31](http://html1.mh-extra.com/html/g-power-america/gn5250dcs/gn5250dcs_owners-manual_3078854031.webp)
5250W Dual Fuel Generator
30
CO-Seizer ™ CARBON MONOXIDE PROTECTING SYSTEM
DANGER!
TO PREVENT SERIOUS INJURY AND DEATH FROM
CARBON MONOXIDE INHALATION:
The Carbon Monoxide sensor is an additional layer of protection only. Do not use the Generator in any area or
situation that will allow carbon monoxide to accumulate.
•
FLASHING RED LIGHT:
Dangerous levels of carbon monoxide gas have built up and generator will shut off automatically. Leave
immediately until area has aired out. Move generator to well-ventilated area before operation.
•
FLASHING ORANGE LIGHT:
Carbon monoxide sensor malfunctions. Sensor needs service. Do not use the Generator until the sensor is
working properly. For technical questions, please call 1-877-834-4218.
Carbon Monoxide sensor must only be serviced by qualified technician to restore it to original
settings. Do not modify or tamper with the Carbon Monoxide sensor. Not following these instructions can
result in death or serious injury due to Carbon Monoxide sensor malfunction.
CO seizer alarm
status
1.When the carbon monoxide concentration reaches a dangerous level, the CO seizer will trigger stop
signal. The generator will shutoff and the indicator light will flash red for 5 minutes.
Solutions: Leave immediately until area has aired out to reduce CO concentration and ensure users'safety
2.When the DC output circuit is short-circuited, the CO seizer will trigger stop signal. The generator will
shutoff and the indicator light will flash orange for 5 minutes.
Solutions: 1
、
Check whether there is a short circuit 2
、
Check whether the DC circuit breaker is
disconnected. As that happens , please press the button to reset.