The  Manager contains 16 numbered outputs. Connect the first output to the 
first  Bracket in line. This will be fed the first pixel information from the mapping 
in the S-Drive II Video Processor. This connection is made using a shielded CAT-5 cable. 
Connect output to the second Bracket in line, continuing until the maximum of 16 
outputs are used. If you wish to connect further brackets, then a second  
Manager will be required. 

5)

 

Using a compatible fibre optic cable, connect the output of the S-Drive II to the input of 
the  Manager on the right hand side of the unit. These connectors are keyed, so 
need to be inserted the correct way around, but they simply push in to lock. To remove 
them, pull gently on the side of the connector only, and it should release. The S-Drive II 
will normally sit at your video control position and therefore the use of fibre optic cable 
allows the fast transmission of data across longer distances. 

6)

 

Should you need to connect further  Manager boxes, they can be daisy chained 
using further fibre optic cables, connecting the output of the first, to the input of the 
next, and so on. 

7)

 

Connect your desired configuration of  Lines to the  Brackets. The 
connection between these two elements is via a keyed 4 pin connector. Ensure that 
both connector components are correctly aligned and push them together. The male 
side of the connector has a locking ring which needs to be turned a quarter turn 
clockwise until you feel it physically ‘click’ into place and will not turn further. Once 
‘clicked’  a firm connection has been made. To undo these connectors, turn the locking 
ring anti-clockwise a quarter turn before attempting to pull the connector apart. 
Sequential  Lines can be connected using the same method. 

8)

 

Each  Line has a tab at the first and last sphere. These are for the specific 
purpose of attaching a secondary safety wire, and must be used at the point where a 
 Line connects to a  Bracket. Further safety cables should be used where 
systems are placed above people or objects which may be damaged. 

9)

 

Connect mains power to the  Manager, PSU and S-Drive II units via their power 
inputs. Turn on all units via their onboard switch. 

10)

 

Connect a DVI-D source to the input of the S-Drive II and configure the S-Drive II for your 
desired layout. For further information, consult the S-Drive II user manual. 

 

Once configured, your  system will play back the signal being fed and distributed via the 
S-Drive II. 

Summary of Contents for Solaris +

Page 1: ...User Manual ...

Page 2: ... and follow its instructions especially safety related issues This manual also contains important information in regard to commissioning Be sure that this documentation is forwarded when the product is passed on to third parties These instructions should be read are retained Should you believe that your product was damaged in transit please file a report with the forwarder immediately otherwise an...

Page 3: ......

Page 4: ...to the relevant user guides Solaris system components overview S Drive II Video Processor This video processor receives an external DVI D source to be played on a Solaris system It is configured using some free of charge proprietary G LEC software A fibre optic output is sent to the Solaris Manager Solaris Lines Available in various standard lengths Solaris Lines are cables mounted with LED sphere...

Page 5: ...input from the PSU a data input from the Solaris Manager along with 4 outputs for Solaris Lines It can be mounted by attaching a coupler to the central hole or via the two M10 threaded sockets at the ends of the Bracket Solaris Power Supply Unit PSU The Solaris PSU receives a mains voltage signal and has 8 outputs each of which connects to a Solaris Bracket ...

Page 6: ...is Manager receives a fibre optic signal from the S Drive II and has a fibre optic output to connect further Managers It is powered from a mains voltage input and has 16 CAT 5 outputs which feed signal to the Solaris Brackets G LEC Software Available for free download from www g lec com ...

Page 7: ...o the output from the Solaris PSU there are 8 outputs on each PSU The connection is made through a cable with a Neutrik Speakon connector on each end These connectors are keyed to only connect one way There is no specific sequence in regard to connecting the Solaris Bracket to the output of the PSU but care must be paid to ensure that any maximum load is not exceeded as follow Note that the top 4 ...

Page 8: ...next and so on 7 Connect your desired configuration of Solaris Lines to the Solaris Brackets The connection between these two elements is via a keyed 4 pin connector Ensure that both connector components are correctly aligned and push them together The male side of the connector has a locking ring which needs to be turned a quarter turn clockwise until you feel it physically click into place and w...

Page 9: ...a flat table Carefully remove the optical fiber head by hand Gently move the optical fiber several times on the clean cloth to remove any dirt To clean fiber optic connectors Insert the swab into each optical opening Gently rotate the swab several times and pull it out to remove any dirt To clean Solaris Spheres and Lines To clean the Solaris lines and spheres you should use a slightly damp cloth ...

Page 10: ...ercon connector needs to be inserted and turned clockwise to lock into place and make a connection Check the fuses on the units and replace if blown Problem The video signal is playing but the output from each Bracket is backwards Possible solutions The brackets are plugged into the Solaris Manager in the wrong order Try connecting them in the opposite order if this problem is repeated across all ...

Page 11: ...ingle One ball on 12 cm line G933012 S Drive II Video processor for Solaris with DVI D input G944013 Fiber Optic Cable 20m G944015 Fibre Optic Coupler metal G944004 CAT 5 Ethernet Cable 2m G944005 CAT 5 Ethernet Cable 5m G944006 CAT 5 Ethernet Cable 10m G944042 Speakon Cable 2 5m G944022 Speakon Cable 5m G944007 Blank line extension cable 0 96m G944008 Blank line extension cable 1 92 m G955009 Fli...

Page 12: ...mm 9 x 17 x 3 5 inches 19 2U high Solaris PSU 300 x 430 x 88mm 12 x 17 x 3 5 inches 19 2U Solaris Bracket 500 x 50 x 40mm 20 x 2 x 1 5 inches Optical Pixel Pitch 120mm 4 7 inches Pixel 2 x 3 color SMD LED Pixel density 64 pixels m Where pixels are set at 120 x 120mm grid Colors 16 million 24 48bit full color Electrical Power 0 5 Watts Pixel at 100 full bright white Manager Data output for 16 Brack...

Page 13: ......

Page 14: ......

Reviews: