Fzone FZ-ATO User Manual Download Page 11

If the buzzer alarm turn off, there is only 

LOW

MID

HIG

 lights flash, no 

buzzer alarm.
The reasons of failure will be the following situations:

Failure

Situation

Reasons

Pumping 

failure

Long beep

ATO light flashes slowly

PAUSE light flashes quickly

The water pump is broken.

The water level drops too much 

artificially, and the two SPT pumping 

time still cannot reach the LOW level.

The water pipe is bent and cannot 

pump the fish tank with water.

Sensor 

failure

Buzzer alarm rings every 0.5second

The HIG light flashes every 0.5second

LOW light does not turn on

 The sensor in the tank is dirty, 

blocked by debris of plants, mud or 

other stuff.

 The water surface or tank wall is 

dirty.

Device 

failure

 Long beep for three seconds, beep 

twice

 Controller need be restarted or 

exchanged

Chapter VII: Alarm Situations

11

Summary of Contents for FZ-ATO

Page 1: ...USER MANUAL Aquarium Water Auto Top Off System FZ ATO Web www fzaqua com Email service fzaqua com Facebook www facebook com Fzoneaqua Messenger Fzoneaqua...

Page 2: ...w Chart Chapter IV Precautions Chapter V How to Install the ATO 4 1 Check before Install 4 2 Installation Diagram 4 3 Installation Steps Chapter VI Advanced Settings Chapter VII Buzzer Modes and Setti...

Page 3: ...sly for 5 seconds hear a beep the device starts the initialization SPT When the device is initialized it will calculate the SPT single pumping time according to the size of the tank LOW LOW light or L...

Page 4: ...sizes tanks it will calculate the SPT for new tank Only suitable for TRANSPARENT glass or acrylic RIMLESS tanks Non TRANSPARENT tanks will block the sensors that will lead to overpump accidents Chapte...

Page 5: ...wer than LOW level the LOW light will turn off and the water pump will start the 1st pumping for a SPT period If the water level reaches the MID or HIG level the pump will stop pumping water If the 1s...

Page 6: ...e their own anti siphon valve according to their needs The installation location of the controller must be clean The internal magnetic module must be clean to avoid optical sensor malfunction of the e...

Page 7: ...get water level between LOW and MID Step 2 Manually fill the water close to the Low Neither exceed the middle line of the LOW and MID nor lower more than 1cm of the LOW light Note The initial water le...

Page 8: ...s follow If the initial water level is lower than the LOW level the STP period is equal to the 50 period from the start of pumping until the water level reaches the MID level If the initial water leve...

Page 9: ...ore than 20 minutes the buzzer alarm will be triggered No alarm in less than 20 minutes is to prevent from triggering the HIG level when feeding the fish Note This function can be turned off After it...

Page 10: ...rt setting press Pause and LOCK simultaneously for 3 seconds you will hear a beep and then you hear three sound periods di didi and dididi Select mode after the di sound press the Pause key to select...

Page 11: ...artificially and the two SPT pumping time still cannot reach the LOW level The water pipe is bent and cannot pump the fish tank with water Sensor failure Buzzer alarm rings every 0 5second The HIG lig...

Page 12: ...THIS PRODUCT IS INTENDED FOR AQUARIUM USE ONLY KEEP IT AWAY FROM CHILDREN Web www fzaqua com Email service fzaqua com Facebook www facebook com Fzoneaqua Messenger Fzoneaqua...

Reviews: