background image

5. OPERATION

Page 6

00

:

00

100

2. Manual Mode
      a. Press the button “Auto” to shut down the automatic mode. 
      b. Press the button to select "Routine" or "Pulse”.
      c. Press the button "Start".
      d. The curing distance between the cassette and paint surface should be set according to 
           the paint material and weather(air humidity). Usually, keeping a distance of about 
           35-45cm from the paint surface is recommended.
      e. The curing time and power should be set according to the requirements of the paint 
           material. Usually, "Pulse" is set to 5 mins and "Routine" to 10 mins.
      f.  Press the button “Start/Stop”.
      g. Turn off the equipment when the work is completed.

3. Pulse Mode
      a. Press the button “Auto” when the lamp is ready to use to shut down the automatic 
          mode. Set power and time. Press the button “Pulse".
      b. Press the button “Start/Stop".
      c. The curing distance between the emitters and paint surface should be set according to 
          the material of paint and weather (air humidity). Usually, keeping a distance of about 
          35-45cm from the paint surface is recommended.

      d. After this program is completed, the system is able to carry out other programs. Make 
           sure to turn off the system when the equipment is not in use.

Time Adjustment

Power

 

Adjustment

Summary of Contents for FY-6CH

Page 1: ...Instruction Manual Our equipment is approved by the following car manufacturers FY 6CH ...

Page 2: ...CONTENTS 1 Precautions 2 Specifications 3 Installation 4 Controls 5 Operation 6 Troubleshooting 1 Troubleshooting 2 Light Tube Replacement 7 Exploded View 8 Circuit Diagram 1 2 3 4 5 7 8 9 10 ...

Page 3: ...staller or service agency 4 The system has been designed for easy installation low operating costs and minimal maintenance The warranty does not cover lamp tube defects resulting from misuse or improper operation 5 Disconnect power source when the equipment is not in use for a long time 6 The light tube should not be perpendicular to the ground when the equipment is in operation Otherwise it will ...

Page 4: ...odel Input Voltage Input Power Curing Area Temperature Time Setting Light Intensity FY 6CH 380V 1 ph 50 60Hz 6 1000W 1800 1000mm 35 C 100 C adjustable 0min 99min adjustable 10 100 2 SPECIFICATIONS Page 2 ...

Page 5: ...Usually the wheels with brakes should be mounted on the rear of the base 2 Installation of the column a Open the packing of the column b Put the column vertically on the top of the base directly engage the screw holes and tighten up using the screws c Connect the support arm with the column for supporting the cassette d Connect the lifter with the column to control the up and down movement of the ...

Page 6: ... 7 Lamp selector each lamp can be controlled separately 8 Pulse 9 Routine 10 Auto 11 Nearest distance adjustment press this button first then press Button 6 to adjust the nearest distance 12 Farthest distance adjustment press this button first then press Button 6 to adjust the farthest distance 13 Start Stop Press Auto Button 10 after switching on the power to set parameters such as time power dis...

Page 7: ...e set according to the paint material and weather conditions air humidity Usually keeping a distance of about 35 45cm from the paint surface is recommended d Press the button Start Stop to start automatic curing mode Once the automatic mode is selected two related cure programs become available to the user Program 1 2 Fig A and Fig B e Protect the lamp against shocks and vibrations when the lamp i...

Page 8: ...e is set to 5 mins and Routine to 10 mins f Press the button Start Stop g Turn off the equipment when the work is completed 3 Pulse Mode a Press the button Auto when the lamp is ready to use to shut down the automatic mode Set power and time Press the button Pulse b Press the button Start Stop c The curing distance between the emitters and paint surface should be set according to the material of p...

Page 9: ...tube damaged b Lamp is not plugged in c Control silicon damaged a Control silicon damaged a Unplugged flat wire in circuit board b Digital display damaged a Switch imbalance b Keyboard has exclusion SOLUTION a Check light tube b Check the connections c Check control silicon a Check control silicon a Check flat wire b Check digital display a Check the installation of switch b Check keyboard exclusi...

Page 10: ...plates from both ends of the cassette d Remove the fixed plates from both ends of the cassette e Loosen fixed screws and cut off connections the light tube can be replaced f Repeat the steps above in reverse order to replace the light tube Prepare the cassette which needs 6 TROUBLESHOOTING Page 8 ...

Page 11: ...cting rod Clamping bar NAME Cassette Distance sensor Plastic nut Connector right Handle Lower connecting rod Upper connecting rod Lifter NAME Lifter handle Front wheel U type base Back wheel Cover plate lower Relay Flange Power switch NAME Control silicon Handle Transformer Cover plate upper Circuit board Page 9 1 2 3 4 5 6 7 8 9 10 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 28 27 29 ...

Page 12: ...8 CIRCUIT DIAGRAM Page 10 O U T IN F L 1 L 2 L 3 PCB GND CON DC1 2 V G ND C ON D C12 V Control Silicon Control Transformer Power Switch Fan A C Contactor PCB for Distance ...