5. OPERATION
Page 6
00
:
00
100
2. Manual Mode
a. Press the button “Auto” to shut down the automatic mode.
b. Press the button to select "Routine" or "Pulse”.
c. Press the button "Start".
d. The curing distance between the cassette and paint surface should be set according to
the paint material and weather(air humidity). Usually, keeping a distance of about
35-45cm from the paint surface is recommended.
e. The curing time and power should be set according to the requirements of the paint
material. Usually, "Pulse" is set to 5 mins and "Routine" to 10 mins.
f. Press the button “Start/Stop”.
g. Turn off the equipment when the work is completed.
3. Pulse Mode
a. Press the button “Auto” when the lamp is ready to use to shut down the automatic
mode. Set power and time. Press the button “Pulse".
b. Press the button “Start/Stop".
c. The curing distance between the emitters and paint surface should be set according to
the material of paint and weather (air humidity). Usually, keeping a distance of about
35-45cm from the paint surface is recommended.
d. After this program is completed, the system is able to carry out other programs. Make
sure to turn off the system when the equipment is not in use.
Time Adjustment
Power