The shortwave infrared curing lamp is divided into 3 parts (a base, a frame and a cassette)

   

1)  Installation of the base:

           a.  Open the packing of the base.

     

b.  Install the four wheels on the base and tighten up the screws.

                 Usually, the wheels with brakes are mounted on the rear of the base.

   

2)  Installation of the frame:

           a.  Open the packing of the frame.

     

b.  Put the column onto the top of the base, line up the screw holes and tighten up 

                 with screws.

  

  3)  Installation of the cassette:

     

a.  Open the packaging of cassette with care.

     

b.  Connect cassette with holder and tighten up by screws.

     

c.  Connect control wires and adjust the angle of the lamps.

Page 3

3. Installation

1.  Main switch
2.  Control box
3.  Cassette
4.  Cassette
5.  Holder
6.  Column
7.  Base
8.  Caster

8

7

1

2

5

6

4

3

Summary of Contents for FY-2HX

Page 1: ...Instruction Manual FY 2HX Our equipment is approved by the following car manufacturers China...

Page 2: ...Contents 1 2 3 4 5 6 1 Precautions 2 Specifications 3 Installation 4 Controls 5 Operation 6 Troubleshooting 1 Troubleshooting 2 Lamp Tube Replacement 7 7 Circuit Diagram 8...

Page 3: ...llation and servicing must be performed by a qualified technician or service agency 4 The system has been designed for easy installation low operating cost and minimum maintenance The warranty does no...

Page 4: ...mm Time Setting Light Intensity FY 2HX Single Phase 220V 50 60Hz 2 1000 1200 1000 0 99mins Adjustable 10 100 Rust proof primer 4 8 mins Intermediate primer 2 3 mins Primary filler 5 8 mins Secondary f...

Page 5: ...he base 2 Installation of the frame a Open the packing of the frame b Put the column onto the top of the base line up the screw holes and tighten up with screws 3 Installation of the cassette a Open t...

Page 6: ...PRIMARY FILLER PRIMER TOP COAT VARNISH Page 4 4 Controls 1 Voltage 2 Curing time 3 Time 4 Time 5 6 Lamp selector 7 Rust proof primer 8 Intermediate primer 9 Primary filler 10 Secondary filler 11 Top...

Page 7: ...ly keeping a distance of 45cm from the paint surface is best 5 Protect the lamp against shocks and vibrations especially when it is cold 6 During the curing process the paint surface must be clean wit...

Page 8: ...b Lamp is not plugged in a Unplugged flat wire in circuit board b Digital display damaged a Switch imbalance b Key board has exclusion a Check light tube b Check the connections a Check flat wire b Ch...

Page 9: ...2 Remove the grille of cassette 3 Remove the plates from both ends of the cassette 4 Remove the fixed plates from both ends of the cassette 5 Loosen fixed screws and cut off connections the lamp can b...

Page 10: ...7 Circuit Diagram Page 8 220V 0V Over Current Protection Switch Power Switch A C 2 2 0 V Lamps Control Transformers 12V PCB B oa r d 0V...

Reviews: