1)  Troubleshooting

Page 6

Lamp tube does not work

1) Lamp tube damaged

2) Lamp not plugged in

3) SCR damaged

Lamp tube lights all the time

1) SRC damaged

Digital display does not work

or is incomplete

1) Flat wire unplugged in 

     circuit board

2) Digital display damaged

Can not adjust temperature 

and time switches 

PROBLEM

CAUSE

SOLUTION

1) Check lamp tube

2) Check connections

3) Check SCR

1) Check SCR

1) Check 

 

2) Check digital display

flat wire

1) Potentiometer damaged

2) Timer damaged

1) Check whether the 

     potentiometer is in proper 

     working condition

2) Check whether the timer is 

     in proper working 

     condition

6. Troubleshooting

Summary of Contents for FY-1WH

Page 1: ...Our equipment is approved by the following car manufacturers China Instruction Manual FY 1WH...

Page 2: ...Contents 1 2 3 4 5 6 1 Precautions 2 Specifications 3 Installation 4 Controls 5 Operation 6 Troubleshooting 1 Troubleshooting 2 Lamp Tube Replacement 7 7 Circuit Diagram 8...

Page 3: ...Installation and servicing must be performed by a qualified installer or service agency 4 The system has been designed for easy installation low operating costs and minimal maintenance The warranty d...

Page 4: ...age 2 2 Specifications Model Input Power Source Input Power W Curing Area mm Temperature C Time Setting Light Intensity FY 1WH Single Phase 220V 50 60Hz 1000 800 450 0 60 mins Adjustable 10 100 35 100...

Page 5: ...the rear of the base 2 Installation of the frame a Open the packing of the frame b Put the column onto the top of the base line up the screw holes and tighten up with screws 3 Installation of the cas...

Page 6: ...5 6 7 8 4 Controls Page 4 1 Time display 2 Temperature display 3 Pulse paint curing 4 Routine paint curing 5 Time adjustment 6 Temperature adjustment 7 Start 8 Stop 9 Lamp selector Circuit breaker mus...

Page 7: ...Adjust the distance from heat source to paint surface usually keeping a distance of 45cm from the paint surface is the best The lamp should also be kept parallel to the paint surface 5 Protect the la...

Page 8: ...e unplugged in circuit board 2 Digital display damaged Can not adjust temperature and time switches PROBLEM CAUSE SOLUTION 1 Check lamp tube 2 Check connections 3 Check SCR 1 Check SCR 1 Check 2 Check...

Page 9: ...lle of cassette 3 Remove the plates on both ends of the cassette 4 Remove the fixed plates from both ends of the cassette 5 Loosen fixed screws and remove connections The lamp can now be replaced 6 Re...

Page 10: ...1 G 2 K 1 K 2 P C B B o a r d 2 2 0 V 0 V G 2 K 2 G 1 K 1 K 1 G 1 K 2 G 2 O v e r C u r r e n t P r o t e c t i o n S w i t c h P o w e r S w i t c h A C 2 2 0 V 0 V 1 2 V 0 V 1 2 V 0 V 1 2 V Control...