InstalationIn

SAVE THESE INSTRUCTIONS

LR: LustroRame

We have developed this series of field installation guidelines to assit you in correctly installing 

fixtures and transformers ensuring customer satisfaction and trouble free service. If you have 

any questions please call your local distributor or the FX Techline at 800-688-1269 before 

proceeding. Follow all NEC guidelines and local electrical codes. 

For further info, see our website: www.FXL.com

DO NOT EXCEED 50 WATTS IN THIS FIXTURE

The main secondary wiring is intended for shallow burial - less thank 6 inches (152mm). This fixture 

should not be installed within 10 feet (1.42m) of a pool, spa or fountain. To relamp, turn lens cap as if 

it is threaded, remove lamp and carefully insert new one. Do not touch the actual lamp bud with fingers 

as this will shorten lamp life. If you do touch lamp bud, clean off with cloth and alcohol. Apply hi-temp 

dilectric grease into socket to prevent moisture damage to lamp base. To install cap start it on an angle 

so it’s halfway on, then twist and push down as if it was threaded. Lens cap can be lubricated on inside 

to ease installation. To minimize clean-up, keep plastic shipping bag on fixture until just before system 

testing.

Eve Mount: Mount as high as possible to allow maximum beam projection. To minimize glare, keep 

the aiming angle 60° to vertical. Conceal fixtures and cables between beams whenever possible. The 

12-16 gauge feed wire should be attached with either nyulon C-clamps with stainless screws or plated 

staples. For high performance and predictable lamp life, supply fixture with between 11 - 11.5 volts 

with all lamps installed and operating. USE FX LUMINAIRE TRANFORMERS ONLY — FX WILL NOT 

WARRANTY OR REPLACE ANY COMPONENTS DAMAGED BY OTHER MANUFACTURER’S EQUIP-

MENT. The FX transformer is specifically designed for the high tech lamps used in our fixtures —the use 

of inferior power supplies can cause premature lamp failure and other problems including the risk of fire. 

To order connectors or additional lengths of wire for connection, contact your local distributor.

IMPORTANT SAFETY INSTRUCTIONS: WARNING! TO REDUCE RISK OF FIRE OR INJURY TO PER-

SONS: Turn off/ unplug and allow to cool before replacing lamp — lamp gets HOT quickly! Contact 

only switch/plug when turing on. Do not touch hot lens, guard or enclosure (*See drawing for location 

of lens). Keep away from materials that may burn. Do not touch the lamp at any time. Use soft cloth. Oil 

from skin may damage lamp. Do not operate the luminaire fitting with missiong or damaged sheild. 

For 50w LR: Lighted lamp is HOT!

Installation Guidelines:

Why use the LiteSplice?

Step 1

Step 2

Step 3

Step 4

Step 4

Step 3

Without  a  waterproof  splice  connection  any 

system  will  develop  voltage  loss  and  low  grade 

shorts making your lighting professional life hell.  

Below is our proven method of insuring you and 

your client years of trouble free high performance 

from the FX System.  

FX Does NOT recommend the use of Quick 

Clip style connectors or Pre-filled wirenuts 

because they are not waterproof and will 

rot out creating resistance and shorts.  A 

little more time spent during installation 

is repaid handsomely in reduced service 

calls.

Begin with a 12, 10 or 8 gauge direct burial low 

voltage cable mainline. (Use stranded 12 gauge 

THHN (120v style) wire for conduit runs such as 

wall lights or trellis lights).

Cut  the  mainline  cable  in  half  and  strip  back 

3/4” of the insulation from each side to expose 

the multi-stranded copper conductor.

Join one of the fixture’s conductors to each side 

of the mainline as shown in the diagram. Since 

there is no polarity in low voltage, it doesn’t mat-

ter which side is which when joining the conduc-

tors together.  Install a wirenut on each side.  Now 

is the time to test the individual circuits (cables) 

for voltage drop.  If you were a good boy and 

followed the Circuiting Guidelines included with 

the FX MultiTap Transformer you should be able 

to provide each fixture with between 10.5 - 11.5 

volts with all lamps installed and operating.  Test 

now before you install the SpliceGel because it’s 

easier  to  stick  the  VoltMeter’s  probes  inside  the 

wirenuts to get a reading.

Pump about two squeezes of SpliceGel into the 

baggie and insert both wirenut connections into 

it.  Push out the air and work the Gel into the 

bottom of the wirenut assuring a waterproof con-

nection.  Install the cable tie as shown and cinch 

down to complete the most cost effective perma-

nent waterproof low voltage connection known 

to man.  The Gel will set-up rock hard in about 

3 days.  It’s best to leave 12-18” of slack at each 

fixture to allow for relocation or if you need to 

splice in additional cables in the future.  Since 

this  is  a  permanent  splice  solution  —  you  will 

need to cut it off and start from scratch to add 

cables to the splice.

Standard Spike Mount

RISK OF FIRE WARNING:

DO  NOT  USE  FX  FIXTURES  WITH  ANY 

STYLE  OF  TRANSFORMER  THAT  EXCEEDS 

14 VOLTS ON THE SECONDARY. 

For a complete listing of 

installation details go to 

www.fxl.com/learning/

installation_notes.htm

INSTALLATION NOTES

SECTION/ELEVATION

FOR SERVICE.

COILED BELOW FIXTURE

LEAVE 18" MIN. LOOP

WITH FX LITESPLICE.

LOW VOLTAGE CABLE

FINISHED GRADE

AND DIRT TO DRAIN OFF LENS CAP.

OFF VERTICAL TO ALLOW WATER

AIM FIXTURE A MINIMUM OF 10˚

SPREAD, AND ACCESSORIES.

SEE PLAN LEGEND FOR WATTAGE, BEAM

FX LUMINAIRE LUSTRO RAME FIXTURE.

C   2004 FX LUMINAIRE

ø2.40"

6.50"

8.00"

LUSTRO RAME (LR)

FX LUMINAIRE - SPIKEMOUNT

SCALE:  NOT TO SCALE

This  product  is  an  Uplight  only.  