FWE MOBILE HUMI-TEMP HEATED HOLDING CABINETS
9
LOW TEMP ALARM OPERATION
Unit has a built in “
Low Temp Alarm
”, allowing the operator to have
an audible and a visual indicator that the heated cabinet
temperature falls below the "Low Temperature" set point for more
than
six (6) minutes.
1)
Adjust Set Point
: Turn unit on and rotate knob to off position.
Then hold the "Low Temp Alarm" button for roughly six seconds until
the LTA is displayed on screen, release LTA button and adjust knob
to desired LTA setting. Once correct setting is displayed press the
LTA button to confirm. Unit will beep once LTA will be displayed then
the word "ON" then set LTA temperature. When the internal cabinet
temperature falls below the desired "Set Point" for more than
six (6)
minutes
, the audible and visual alarm will alert you to this condition.
2)
Recall Set Point
: Press "
LOW TEMP ALARM
" key.
Display shows LTA set point for three seconds then reverts to
normal display.
3)
Acknowledge
: Press any key to cancel beeping
For Every
ten (10) seconds
, the display will show LTA for
one (1)
second
until temperature increases above LTA set point.
Note:
The Low Temp alarm will auto-reset once Oven Setpoint is
reached again. The idea is if the user has perhaps left the door
open, the LTA alarm sounds to remind them to close it, with the user
pressing either key to stop the beeping. Once the door is closed and
the oven temperature rises again to oven setpoint, the control
re-enables the LTA alarm in case the user fails to close the door
again.
4)
Disable
: Follow the adjustment steps above.
A rotation of the dial "down" below 90°F (32°C) turns the alarm
feature off.