high-temperature  and  moisture,  or  condensation,  and  under 
direct daylight radiation for a long time.   

u

  For replacing battery, please confirm testing wire has moved 

apart  the  meter,  and  FUNCTION    SWITCH  rotary  switch  is  in 

OFF

 position.   

u

  Please put the used batteries in appointed collection place.   

u

  When replacing the battery with the meter, make sure that the 

test  line  has  been  removed  from  the  meter  and  the  meter  is 
turned off.   

u

  When the meter displays battery low voltage symbol

     

and need to replace the battery in time.   

u

  Pay  attention  to  measuring  range  and  usage  environment 

stipulated for the Tester.   

u

  This  measuring  device  is  only  to  be  used,  disassembled, 

adjusted and repaired by qualified personnel with authorization.   

u

    When it may cause hazard by continuous use for the reason 

of the Tester itself, it shall immediately stop using it and deposit it 
at once, leaving it for disposal by authorized agency.   

u

  For  risk  of  danger  icon  in  manual

,  users  must  perform 

safety operations strictly in compliance with the manual content. 

 

 

 

II. Introduction 

 

Ground  Resistance 

  Soil  Resistivity  Tester  also  known 

as  Four-Wire  Ground  Tester,  Precision  Ground  Resistance 
Tester

,  etc.,  is  a  commonly  used  meter  for  measuring  grounding 

resistance.  It  adopts  a  large  LCD  gray-white  screen  backlight 
display  and  microprocessor  technology  to  meet  the  requirements 
of  two-wire,  three-wire  and  four-wire  test  resistance  and  soil 
resistivity  test. 

Suitable  for  telecommunications,  electricity, 

Summary of Contents for FR3010

Page 1: ...0...

Page 2: ...Operation Methods 9 1 Switch On Off 9 2 Battery Voltage Check 9 3 Ground voltage measurement 10 4 Wire Resistance Verification 10 7 Two wire easy Test Grounding Resistance 14 8 Soil Resistivity Test...

Page 3: ...uring measuring u Pay attention to words and symbols stick on the Tester u It shall make sure that tester and accessories are in good condition before use it can be used only when there is no damaged...

Page 4: ...only to be used disassembled adjusted and repaired by qualified personnel with authorization u When it may cause hazard by continuous use for the reason of the Tester itself it shall immediately stop...

Page 5: ...the auxiliary grounding resistance value At the same time store 500 sets of data resistance measurement range 0 01 30 00k grounding voltage range 0 01 600 0V III Measuring Range and Accuracy Remark 1...

Page 6: ...e Conditions 100 Operating Conditions 5k Range Grounding resistance 0 00 to 30 00k Soil resistivity 0 00 m 9999k m Ground voltage 0 00V to 600 0V Measurement Method Precision 4 wire 3 wire measurement...

Page 7: ...Earth resistance soil resistivity about 7 seconds time Circuit Voltage below AC 600V Data Storage 500 sets MEM icon storage indicator flash display FULL icon to indicate storage is full Data Read Dat...

Page 8: ...losure it is 500V Withstanding Voltage AC 3700V rms Between circuit and enclosure Electromagnetic Features IEC61326 EMC Protection Type IEC61010 1 CAT III 300V CAT IV 150V Pollution Degree 2 IEC61010...

Page 9: ...lectrode and S voltage electrode and according to the formula R V I Calculate the ground resistance value R In order to ensure the accuracy of the test a four wire method was designed to increase the...

Page 10: ...ng distance is a m and the soil resistivity value is obtained according to the formula 2 aR m and the distance between the HS pitch and the S FR is equal both a that is Wenner method For ease of calcu...

Page 11: ...und voltage test Note the difference from the commercial AC voltage test See the following figure After the meter auxiliary grounding rod and test line are all connected after turning on the power tur...

Page 12: ...easured grounding body auxiliary grounding bar test clip and the input interface of the instrument to the measurement eliminating the effect of the wire resistance to the measurement It is better than...

Page 13: ...m or a geodetic grounding system the user can choose a longer test line and the electrode spacing is greater than 5 times the maximum diagonal length of the tested network As shown below R r1 r2 r3 r4...

Page 14: ...sistance Three wire test As shown in the figure below short circuit the FR and E interfaces of the instrument that is the three wire test and the instrument operation is the same as the four wire test...

Page 15: ...the selected metal auxiliary grounding body should be removed during measurement Floor Wiring as shown below the instrument operation with the four wire test When using the commercial power system gro...

Page 16: ...ture content the soil resistivity will also change significantly Therefore in order to have a correct basis in the design of the grounding device so that the designed grounding device can more meet th...

Page 17: ...rod press the key shortly to move the cursor press or key to change the current number size a value range 1m 100m and then press the SET key more than 3 seconds to save the set a value and return to t...

Page 18: ...eep beep alarm sound The maximum value of the ground voltage alarm setting is 100V the maximum value of the ground resistance alarm setting is 3000 and the maximum value of the soil resistivity alarm...

Page 19: ...ng SET button for not deleting and return data reading status selecting YES and then pressing SET button for deleting stored data and it will show as above right figure after deletion IX Battery Repla...

Page 20: ...19...

Page 21: ...ZhengNeng Electronics Technology Co Address 2F No 15 Baoshu Road Taihe Baiyun District Guangzhou Guangdong China Toll free call 4000 1515 38 Tel 86 20 36544172 Fax 86 20 37319075 Post 510540 WebSite w...

Reviews: