F
u t u r e
S
a f e
S E C U R I T Y
NX 4/8 USER GUIDE
www.futuresafesec uri ty.c o m .au
02 9343 0033
Page 1: ...Fu t u r e Sa f e S E C U R I T Y NX 4 8 USER GUIDE www futuresafesec uri ty c o m au 02 9343 0033...
Page 2: ...Zones 8 Group bypass 8 Changing adding user codes 9 Deleting a User Code 10 Walk Test 10 User Code Authorisation 11 Setting the Door Chime 11 Exit Mode 12 Code Pad Emergency Keys 12 Viewing Alarm Memo...
Page 3: ...e not ready will not create an alarm Function Code A Function Code is either a four 4 or six 6 digit code that has been programmed by the installer to operate a device Group Bypass An option that allo...
Page 4: ...Page 3...
Page 5: ...le condition On Light The on light is on when the system is armed The on light is off when it is disarmed Partial Light The partial light is on when the system is armed in the Partial Mode All non byp...
Page 6: ...of an exit delay and beeps 1 second at the end of the exit delay Pulses when the armed status changes and the AC power is off Pulses when the armed status changes and any zone s is bypassed Pulses wh...
Page 7: ...bout to expire Key Sequence Operation Example shows a User code of 1234 being used to set the system to the ON Mode FULLY ARMING THE SYSTEM QUICK ARM MODE 1 2 ON is used when the user is away from the...
Page 8: ...TIAL key The bypass light will illuminate if any zone s is bypassed The light s corresponding to the bypassed zone s will illuminate alerting the user that a zone s may be unprotected and can be fault...
Page 9: ...disarmed any zones which have been temporarily isolated or bypassed will be reset and will therefore be protected when the system is armed again To manually un bypass zones perform the bypassing proce...
Page 10: ...ES On occasion you may need to change your arm disarm codes either as a security measure or for your own convenience User Codes are 4 digits long and must all be different to each other A master Code...
Page 11: ...5 0 3 3 4 WALK TEST Walk test is used to test the functionality of your entire zones and should be performed regularly When in walk test mode the code chime sounder will sound each time a zone is act...
Page 12: ...3 4 SETTING THE DOOR CHIME Chime Mode provides only an audible warning at the premises A ding dong is sounded from the code pad when the protected area is entered for example when an infant opens the...
Page 13: ...code pad to provide support in the areas of personal safety medical alert and fire alarm You must hold these keys for two 2 seconds to activate these functions You should press these keys only in an e...
Page 14: ...s and will light steady those zones that were bypassed during the last alarm RESET LATCHED ALARMS To reset Smoke Detectors Zone Troubles and Zone Tampers the Reset Latched Alarms function must be used...
Page 15: ...Enter the day of the week 1 Sunday 7 Saturday Eg 3 for Tuesday 4 Enter the month code This must always be two 2 digits Eg 0 7 for July 5 Enter the day code This must always be two 2 digits Eg 0 5 for...
Page 16: ...hows setting time as 9 30am 1 Press 9 7 2 Enter the master code 3 Enter the hour code which must be two 2 digits Eg 0 9 for 9am 4 Enter the minutes code which must be two 2 digits Eg 3 0 for 30 minute...
Page 17: ...e formats are selected To program a new phone number you must do the following Key Sequence Operation 1 Press 2 Enter 4 2 for the location of phone number 2 Enter 4 1 for phone number 1 and 4 3 for ph...
Page 18: ...he master code You are now in the view mode and the first phone digit will be displayed Use the following table to read the code pad lights 4 Press the key to move to the next digit s 5 Press to end a...
Page 19: ...4 Press the BYPASS key 5 Press to end and exit 4 1 1 2 3 4 SET CODE PAD TONES Each code pad can have its sounder tone frequency adjusted to your individual requirements Follow the steps bellow to adj...
Page 20: ...irens and communicator should be tested regularly The key sequence below is used to perform the siren and communicator test Key Sequence Operation 1 Enter keys 4 4 to initiate the test option 2 Enter...
Page 21: ...wing which zone s has a low battery This only applies to wireless zones Press the key to return to the 1 of 8 service lights 4 ZONE LOSS OF SUPERVISION Press the 4 key and the zone light s will illumi...
Page 22: ...ZONE DESCRIPTIONS 24 HOUR PARTIAL MODE ENTRY EXIT 1 2 3 4 5 6 7 8 INSTALLATION COMPANY DAS 4 8VerteX 1200A...