Chapter 3 Programming
Chapter 3 Programming
Press for 4 seconds to enter setup mode. Press to select parameter. The
display will indicate the parameter symbol and the value ( or selection ) for that
parameter.
INPT: Selects the sensor type and signal type for the process input.
INPT:
UNIT: Selects the process unit.
UNIT:
RESO: Selects the location of the decimal point (Resolution) for
most (not all) process related parameters.
RESO:
IN.LO: Selects the low scale value for the Linear type input
IN.LO:
IN.HI: Selects the high scale value for the Linear type input
IN.HI:
Hidden if: T/C or RTD type is selected for INPT
Hidden if:
Hidden if: T/C or RTD type is selected for INPT
Hidden if:
How to use IN.LO and IN.HI:
How to use IN.LO and IN.HI:
If 4-20mA is selected for INPT, let SL specifies the input signal low (ie.
4mA), SH specifies the signal high (ie. 20mA), S specifies the current
input signal value, the conversion curve of the process value is shown
as follows:
IN.LO
process value
PV
IN.HI
SL
SH
S
input signal
34
UM L41-Rev 2