Futurecom 2098B-VRX10007800 User Manual Download Page 15

8A087X02 DRAFT 0.2 

VRX1000 

User’s Guide 

 

 

June 2015 

 

Page 15 of 20 

Powering up the VRX1000 

The VRX1000 powers up together with the MSU. The power up mode and channel are 
programmable. Depending on the programmed personality, the VRX1000 can power up 
in one of the following states: 

  VRX1000 Disabled mode, last selected VRX1000 channel 

 OFF 

mode 

  SYSTEM mode, last selected VRX1000 channel 

  SYSTEM mode, preprogrammed VRX1000 channel 

  LOCAL mode, last selected VRX1000 channel 

  LOCAL mode, preprogrammed VRX1000 channel 

  If the VRX1000 powers up on a ‘strapped’ mobile radio channel, the VRX1000 

will be steered according to the Talk Group selected on the MSU. The steering 
may involve both VRX1000 channel and mode change. 

Turning ON the VRX1000 

When the MSU is powered up, the VRX1000 can be activated by one or more of the 
methods described in the following section.  
 

  The VRX1000 is ON when SYSTEM (or optionally LOCAL) mode of operation is 

selected.  

  The VRX1000 is OFF when OFF mode is selected.  

  The VRX1000 is disabled when a “VRX1000 Disabled” Mode / Channel is 

selected on the APX MSU or if the currently selected VRX1000 and MSU modes 
are incompatible (such as TDMA MSU mode and P25 Digital VRX1000 channel). 

 

NOTE: 

The VRX1000 can only be activated when a compatible “VRX1000 Enabled” mode / 
channel is selected on the APX MSU. 

Activating the VRX1000 via the Control Head 

Ensure the MSU is powered up and a VRX1000 Enabled TG / channel is selected on the 
control head. 
To activate the VRX1000: 

 Press 

the 

DVRS

 menu item to enter the ‘DVR/VRX1000 Control Mode’.  

  Once in the ‘DVR/VRX1000 Control Mode’ screen, press the 

MODE

 button to 

toggle the available VRX1000 modes until the desired mode is selected. 

 Press 

the 

SEL

 button or wait the preprogrammed time until the ‘DVR/VRX1000 

control Mode’ screen times out. The last selected VRX1000 mode becomes 
effective. 

  Long press of the 

DVRS

 menu item can be programmed to turn the VRX1000 

ON/OFF. 

Pressing the 

DVRS

 button allows the user to enter the ‘DVR / VRX1000 Control Mode’ 

and to select the desired VRX1000 mode and channel.  

Summary of Contents for 2098B-VRX10007800

Page 1: ...VRX1000 VEHICLE RADIO EXTENDER User s Guide 8A087X02 Draft 0 2 JUNE 2015...

Page 2: ...8A087X02 DRAFT 0 2 VRX1000 User s Guide June 2015 Page 2 of 20 NOTES...

Page 3: ...Requirements for Compliance with Radio Frequency RF Energy Exposure Safety Standards 11 Introduction 12 Identifying Your VRX1000 Model 13 Frequency Band of Operation 13 Cross Band 13 VRX1000 Operation...

Page 4: ...DRAFT 0 2 VRX1000 User s Guide June 2015 Page 4 of 20 Manual Revisions Rev Date ECN Notes References DRAFT 0 1 Oct 28 2014 na DRAFT 0 1 DRAFT 0 11 Apr 30 2015 na DRAFT 0 11 DRAFT 0 2 June 25 2015 na D...

Page 5: ...mplication estoppels or otherwise any license under the copyrights patents or patent applications of Futurecom except for the normal non exclusive license to use that arises by operation of law in the...

Page 6: ...replacement at no charge to Buyer who shall provide labor for the removal of the defective component or item and installation of its replacement at no charge to Futurecom Buyer shall bear all risk of...

Page 7: ...this document NOTE A clarifying statement that expands on the text that follows IMPORTANT An important statement that should be considered and or implemented in order to achieve adequate equipment ope...

Page 8: ...idential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com...

Page 9: ...er transmissions The repeater operator must ensure at all times that no person comes within MPE distance from the vehicle body USA Users Do not use the VRX1000 in the frequency band 406 0 406 1MHz Thi...

Page 10: ...00 Tx duty cycle is defined as Push To Talk PTT 100 Talk IMPORTANT The maximum allowed gain of the 4 Omni directional antenna for the VRX1000 is Unity 0dBd RF Exposure Label The RF Exposure Label shou...

Page 11: ...e with Radio Frequency RF Energy Exposure Safety Standards ATTENTION To ensure compliance with RF Energy Safety Standards Install only Futurecom Motorola approved antennas and accessories and set cond...

Page 12: ...is available and PSU coverage is either intermittent or completely absent Installed in the trunk of a car fire truck armored vehicle ambulance the VRX1000 extends radio communications to the PSU user...

Page 13: ...are classified as follows In Band when the MSU and VRX1000 operate in the same frequency band Cross Band when the MSU and VRX1000 operate in two different frequency bands Cross Band Cross Band VRX1000...

Page 14: ...ings of the MSU that is interfaced to the VRX1000 Configuration capabilities and programmed settings of the radio system Type and programming settings of the portable radios used for communications th...

Page 15: ...ion is selected The VRX1000 is OFF when OFF mode is selected The VRX1000 is disabled when a VRX1000 Disabled Mode Channel is selected on the APX MSU or if the currently selected VRX1000 and MSU modes...

Page 16: ...activate the VRX1000 via the MSU control head Press the DVRS button to enter the DVR VRX1000 Control Mode then press the MODE button until VR OFF is displayed and either press the SEL button or wait f...

Page 17: ...000 Channel Change The VRX1000 mode and channel may be programmed to be strapped to the specific MSU TG channel In this case selecting a specific MSU TG channel would automatically force the VRX1000 t...

Page 18: ...nce 50 Ohms Duty Cycle 50 Receive 50 Transmit External Connectors Antenna Computer Interface Mini UHF Mini USB programming only Single ended input voltage 0 3V 2 8V 12Mbps max 1 MOhm input impedance 3...

Page 19: ...P25 5 BER 115 dBm 115 dBm Frequency Stability 30 C to 60 C 25 C Ref 0 75ppm Selectivity 12 5 25 kHz 60 dB 70 dB Intermodulation 70 dB Spurious Rejection 70 dB Analog Mode Deviation 12 5 25 kHz 2 5 kHz...

Page 20: ...turecom com Orders Please contact Motorola Drop Ship Return Authorizations 1 800 701 9180 Head Office and Manufacturing 3277 Langstaff Rd Concord Ontario L4K 5P8 Canada 905 660 5548 www futurecom com...